Справочник Пользователя для RadioFrame Networks Inc MCSERIESHP10

Скачать
Страница из 131
MC-Series High-Power System 
 
System Definition 
998--01 Rev X1 
RadioFrame Networks, Inc. 
CONFIDENTIAL AND PROPRIETARY 21 
 
 
provides conversion of the 10Base2 connection at the iSC to a 10BaseT connection in 
the BIC. 
Figure 9  CRTC Ports and Indicators 
 
2.2.1.5 BIC 
Ports 
Table 3  Ports in the BIC 
Card 
Port 
Description 
Front 
Ports 1-7 (RJ-45) 
not currently used 
Port 8 (RJ-45) 
Sprint Nextel technician local Ethernet access 
BIC CRIC 
EIA-232 9-pin serial port 
Sprint Nextel technician local serial access 
BPC 
N/A N/A 
Back 
Port 1 (RJ-45) 
CRTC 1 Port 10BaseT 
Port 2 (RJ-45) 
AIC ERTM port 4  
Port 3 (RJ-45) 
CRTC 2 Port 10BaseT (Optional) 
Port 4 (RJ-45) 
not currently used 
Port 5 (RJ-45) 
RF Shelf 1 10/100 Port 1 
Port 6 (RJ-45) 
RF Shelf 2 10/100 Port 1 
Port 7 (RJ-45) 
RF Shelf 3 10/100 Port 1 
Port 8 (RJ-45) 
Remote Ethernet connectivity (DNX-1u Ethernet) 
5 MHz/1PPS IN 
iSC-3 5-MHz/1PPS port 
5 MHz/1PPS OUT 
not currently used (no terminator required) 
ERTM 
GPS ANT 
not currently used 
10Base2 – iSC 
ISC-3 10Base2 port 
CRTC 1 
10BaseT – iSC 
BIC ERTM port 1 
10Base2 – iSC 
ISC-3 10Base2 port 
CRTC 2 
(Optional) 
10BaseT – iSC 
BIC ERTM port 1 
2.2.1.6 BIC 
Indicators 
Each card installed in the BIC has a Power LED and a Status LED that indicates timing 
synchronization. 
Note:  The CRIC Status LED represents PLL status. The system will not go active unless 
this LED is green. 
Each RJ-45 port has an Ethernet link LED that indicates connectivity and an Ethernet 
activity LED that indicates Ethernet traffic (Figure 10).