Table 3: Commissioning Task Explanation 
Commissioning Tasks 
Observation 
1.  On-line and Inquiry status 
 
Activate the OMT Main window. The system Initialization will 
completed in about 2 minutes.  
 
Check the ALM LED for 
the repeater’s status. Proceed if there is no 
alarm; else check the failure and attend to the alarm. 
2.  Isolation detection 
 
Detect isolation of service antenna and donor antenna. 
3.  Set Channel No. 
 
 
Keep RF switch ON and set the 
channel number of the repeater’s 
operating frequency. 
4.  Adjust Downlink Output 
Power and align donor 
antenna 
 
Observe DL input power from measured value. Align the direction of 
donor antenna until the DL input power reading is maximized. 
 
Note: To ensure that the measured DL input power is accurate, one 
should set the DL ATT to “0” before performing the check. 
5.  Configure [Device ID] 
 
Go to [Device Info] and set [Device ID]. 
6.  Comm. Setting 
 
Go to [Management] -> [Comm. Setting] and select communication 
types: [SMS], [PS] or [SNMP]. 
7.  Select Monitoring 
Parameters 
 
Select the equipment controlled and monitored parameters.. 
8.  Test coverage area field 
intensity and adjust service 
antenna. 
 
 
Use test-handset to verify field intensity within the coverage area. If 
needed, realign the service antenna to achieve the desired 
coverage. 
 
Note: If during operation, the equipment gain could not be set to 
maximum or the output power is not high enough due to insufficient 
donor and service antennas isolation, then the antennas’ position 
should be changed to increase isolation. If the output power is too 
high and ALC is activated, then adjust the DL ATT to achieve optimal 
DL Gain.  
9.  Verify UL gain and ensure 
test call produces good 
voice quality and there is 
no interfering BTS 
 
Adjust UL gain and perform test calls. Typically, the UL gain is set 
around 5dB less than DL gain. Perform test calls in the coverage 
area while adjusting UL gain if required.  
 
Note: If the repeater is near the BTS and the test call performance is 
poor, this may be due to UL noise interference to the BTS. Users can 
calculate and determine if the repeater UL noise will interfere with the 
BTS. 
 
Verify again that there is no unacceptable interference to BTS. 
 
 
 
 
 
End of Section