Figure 5.  PAL-650 Tag (disassembled). 
When delivered, the tags are provided with a protective tab (cf. Figure 6) which disconnects the 
internal lithium battery from the rest of the tag circuitry.  Once this tab is removed, the tag is 
activated and can then be used for precision localization applications. 
 
Figure 6.  PAL-650 Tag (before power activation). 
4. General Specifications
Principle of Operation:  Ultra Wideband (UWB) burst transmissions 
(FCC Part 15, Subpart F) 
Frequency:   6.2 
GHz 
Bandwidth: 
 
700 MHz (-10 dB instantaneous) 
Range: 
  50 
meters 
(indoors) 
Update Rate: 
 
1 per second
System Resolution: 
1 foot (3-dimensional)