Airaya Corp GRID-3X3-PS Benutzerhandbuch

Seite von 44
 
 
- 38 - 
Airaya
      
 
 
 
 
WirelessGRID-300 Backhaul 
Ping 192.168.1.70 –t  (leave this ping window running so you can see ping 
results easily) 
 
 
2. 
If there is no response, try IP address 192.168.1.71, or cycle the power on 
bridge end point A.   
 
 
 
 
 
 
 
 
After ~45 seconds, you should see ping responses from 192.168.1.70 (bridge A).   If you 
see ping responses on test station A, you have an IP network connection between test 
station A and bridge A. 
 
If you can ping bridge A, you can open the HTTP configuration utility and network 
management system (NMS) using a web browser.  You will not be able to ping across the 
link to bridge B until WirelessGRID-300 bridge list authorization entries are made in both 
bridges. (See step 3) 
 
3. 
Setup the Ethernet network connection between bridge B and test station B 
using the same procedure described above, then verify that the test station B to 
bridge B setup is correct. 
 
After verifying that both bridges and their respective test stations can 
communicate via Ethernet, go to step 3

 
 
Step 3. Setup bridge software configuration for bridge 
After verifying that both bridges and their respective test stations can communicate via 
Ethernet, you will need to setup and verify bridge configuration so they will be able to 
communicate over the radio link.  The configuration given here will be a minimal 
configuration for test purposes; for more detailed configuration information, please refer 
to the product manual. 
 
 
 
 
 
 
 
1. 
On each test station, open an http session by entering the bridge IP address 
into the address field of your web browser.  The correct format is: 
http://192.168.1.70
, or whatever the bridge’s IP address has been set to.   
Note 
Check that the Ethernet link light is on at test station A if connected directly to bridge A with 
straight-thru cable, or on the switch/router port that bridge A is plugged into if connected 
with a straight-though Ethernet cable. 
If the Ethernet link light is on and you cannot ping bridge A, then re-check IP address and 
NOTE 
Factory default administrative User Name and Password are Airaya with an uppercase A 
As a security measure, the WirelessGRID http configuration utility and network management systems (NMS) 
will timeout if left open with no activity for 3 or more minutes.  You will need to re-login to again access the 