Intel R1304BTSSFAN Benutzerhandbuch
Appendix B: Integrated BMC Sensor Tables
Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
44
Revision 2.0
Intel order number G17455-004
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System Status
Assert/De-
assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-by
Fan Tachometer
Sensors
Sensors
(Chassis specific
sensor names)
sensor names)
30h–
34h
Chassis-
specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc = Degraded
c = Non-fatal2
As and
De
Analog R,
T M
–
Power Supply 1
Status
Status
(PS1 Status)
50h
Chassis-
specific
Power
Supply
08h
Sensor Specific
6Fh
00 - Presence
OK
As and
De
–
Trig
Offset
A X
01 - Failure
Degraded
02 – Predictive Failure
Degraded
03 - A/C lost
Degraded
06 – Configuration
error
OK
Power Supply 2
Status
Status
(PS2 Status)
51h
Chassis-
specific
Power
Supply
08h
Sensor Specific
6Fh
00 - Presence
OK
As and
De
–
Trig
Offset
A X
01 - Failure
Degraded
02 – Predictive Failure Degraded
03 - A/C lost
Degraded
06 – Configuration
error
error
OK
Power Supply 1
AC Power Input
AC Power Input
(PS1 Power In)
54h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R,
T A
X
Power Supply 2
AC Power Input
AC Power Input
(PS2 Power In)
55h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R,
T A
X