Full Sensor Name 
(Sensor name in SDR) 
Sensor 
# 
Platform 
Applicability 
Sensor Type
Event/Reading 
Type 
Event Offset Triggers
Contrib. To 
System Status 
Assert/De-
assert 
Readable
 
Value/Off
sets 
Event
Data 
Rearm
Stand-by 
Fan Tachometer 
Sensors 
(Chassis specific 
sensor names) 
30h–
34h 
Chassis-
specific 
Fan 
04h 
Threshold 
01h 
[l] [c,nc] 
nc = Degraded 
c = Non-fatal2 
As and 
De 
Analog R, 
T  M 
– 
Power Supply 1 
Status 
(PS1 Status) 
50h 
Chassis-
specific 
Power 
Supply 
08h 
Sensor Specific 
6Fh 
00 - Presence 
OK 
As and 
De 
– 
Trig 
Offset 
A X 
01 - Failure 
Degraded 
02 – Predictive Failure 
Degraded 
03 - A/C lost 
Degraded 
06 – Configuration 
error 
OK 
Power Supply 2 
Status 
(PS2 Status) 
51h 
Chassis-
specific 
Power 
Supply 
08h 
Sensor Specific 
6Fh 
00 - Presence 
OK 
As and 
De 
– 
Trig 
Offset 
A X 
01 - Failure 
Degraded 
02 – Predictive Failure  Degraded 
03 - A/C lost 
Degraded 
06 – Configuration 
error 
OK 
Power Supply 1 
AC Power Input 
(PS1 Power In) 
54h 
Chassis-
specific 
Other Units 
0Bh 
Threshold 
01h 
[u] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
T  A 
Power Supply 2 
AC Power Input 
(PS2 Power In) 
55h 
Chassis-
specific 
Other Units 
0Bh 
Threshold 
01h 
[u] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
T  A