Intel R1304BTSSFAN Benutzerhandbuch

Seite von 67
Intel
®
 Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
                                                                                  
Appendix B: Integrated BMC Sensor Tables 
Revision 2.0 
 
 
 
 
45 
Intel order number G17455-004 
Full Sensor Name 
(Sensor name in SDR) 
Sensor 
# 
Platform 
Applicability 
Sensor Type
Event/Reading 
Type 
Event Offset Triggers
Contrib. To 
System Status 
Assert/De-
assert 
Readable
 
Value/Off
sets 
Event
Data 
Rearm
Stand-by 
Power Supply 1 
+12V % of Maximum 
Current Output 
(PS1 Curr Out %) 
58h 
Chassis-
specific 
Current 
03h 
Threshold 
01h 
[u] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
T  A 
Power Supply 2 
+12V % of Maximum 
Current Output 
(PS2 Curr Out %) 
59h 
Chassis-
specific 
Current 
03h 
Threshold 
01h 
[u] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
T  A 
Power Supply 1 
Temperature 
(PS1 Temperature) 
5Ch 
Chassis-
specific 
Temperature 
01h 
Threshold 
01h 
[u] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
T  A 
Power Supply 2 
Temperature 
(PS2 Temperature) 
5Dh 
Chassis-
specific 
Temperature 
Threshold 
01h 
[u] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
T  A 
Processor Status 
(P1 Status) 
70h All 
Processor 
07h 
Sensor Specific 
6Fh 
01 - Thermal trip 
Fatal 
As and 
De 
– 
Trig 
Offset 
M X 
07 - Presence 
OK 
Processor Thermal 
Margin 
(P1 Therm Margin) 
74h All 
Temperature 
01h 
Threshold 
01h 
– – 
– 
Analog 
R, 
– 
Processor Thermal 
Control % 
(P1 Therm Ctrl %) 
78h All 
Temperature 
01h 
Threshold 
01h 
[u] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog 
Trig 
Offset 
A – 
Catastrophic Error 
(CATERR) 
80h All 
Processor 
07h 
Digital Discrete 
03h 
01 – State Asserted 
Non-fatal 
As and 
De 
– 
Trig 
Offset 
M –