RMP60-RMI partnership
continued on next page
System setup is achieved using trigger logic
and powering on the RMI.
Trigger logic is a method that allows user
configuration of the options available in the
RMP60. Trigger logic uses a sequence of
RMP60 triggering and battery insertion
followed by further RMP60 triggering.
This leads the user through a series of choices
allowing selection of the required options.
Reviewing of choices can be made by battery
insertion alone. See RMP60 user’s guide for
full details of reviewing probe settings.
To partner an RMP60 and RMI
Partnering is only required during initial system
set-up. Further partnering is only required if
either the RMP60 or RMI is changed.
Partnering cannot be lost by reconfiguration
of probe settings or when changing batteries.
Partnering can take place anywhere within
the operating envelope.
RMP60-RMI partnership
1. Use trigger logic to access RMP60
configuration mode.
2. Configure turn on method (if not configured).
3. Configure turn off method (if not configured).
4. Enter acquisition mode by deflecting stylus.
5. Remain in acquisition mode off by not
releasing stylus. This allows time to get the
RMI ready for partnering.
6. Power on RMI.
7. Watch the RMI signal LED; after a couple
of seconds the LED will repeatedly flash
on and off green. This is the start of a
10 second interval in which the RMI
is in acquisition mode.
8. Release RMP60 stylus and trigger a
couple of times. This causes the RMP60
to go into (and out of) acquisition mode.