Renishaw plc RMIV2 Benutzerhandbuch

Seite von 31
18
RMP60-RMI partnership
9.
The RMI signal LED will change to
repeatedly flashing red and yellow
(for the remainder of the 10 second
interval) indicating a successful
partnering.
10. Leave RMP60 for 20 seconds to go into
standby.
11. System is ready to use.
Note
To check that turn on and off settings have not
accidentally been changed insert batteries to
review current probe settings.
Note
When holding the RMP60 do NOT wrap a hand,
or anything else, around the glass window.
Note
When the RMP60 and RMI become partners
the RMI records the RMP60 serial number.
It is not possible for an RMI to be partnered
with more than one standard RMP60.
It is possible for an RMP60 to be partnered
with more than one RMI, but the system will
not function correctly.