5. Hardware 
Configuration 
5.1. 
Module Baud Rate Configuration 
The default KwikBlue Module speed is 115200 bps. To use the high-speed driver (921600 bps), you 
must have a high-speed UART (such as Socket’s CF or PC serial cards) that supports this speed and 
the baud rate of the module must be re-programmed. Follow the software install instructions in the 
“Desktop Test Set-up” section: 
1.  Click on the BdAddr to verify that the KwikBlue module is being read from. You should see a 
non-zero 16 byte hex number. 
2.  Select UART_Baud_Rate - change the key to the value you wish to use. Select "Set" to write the 
new value into firmware. 
3.  Power cycle the module for the new firmware changes to take effect. 
5.2. Firmware 
Upgrade 
If firmware upgrades become available, Socket support will assist you in updating your system if 
necessary. 