Appendix A 
Appendix A 
Appendix A 
Appendix A –
–    Error Handling
Error Handling
Error Handling
Error Handling    
 
 
118
118
118
118    
 
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204    User’s Guide
User’s Guide
User’s Guide
User’s Guide    
 
[Handler]
 determines how tag is processed and is a decimal number 
(between 0 and 255) that applies to all tags in the sequence. Where: 
Bit 7:  Password Authentication Indicator 
 
1 = Password Authenticated 
 
0 = Not Password Authenticated 
Bit 6:  Blacklist Indicator  
 
1 = Blacklisted 
 
0 = not Blacklisted 
Bit 5:  TID Authentication Indicator 
 
1 = TID Authenticated 
 
0 = Not TID Authenticated 
Bit 4:  RFU (0) 
Bit 3:  RFU (0) 
Bit 2:  RFU (0) 
Bit 1:  RFU (0) 
Bit 0:  Handler value 
 
1 = Pass Translated ID to WIM 
 
0 = Do not pass translated ID to WIM 
A.11.2.
 
Typical Handler values 
 
1 – Legacy tag whose data is to be passed through the system to the 
Wiegand interface (00000001b) 
 
64 – Black-listed Legacy tag (01000000b). 
 
33 – TID-Authenticated Tag whose data is to be passed through the 
system to the Wiegand interface (00100001b). 
 
96 – Black-listed TID-Authenticated tag (01100000b).  
 
129 – Password-Authenticated Tag whose data is to be passed through 
the system to the Wiegand interface (10000001b). 
 
192 – Black-listed Password-Authenticated tag (11000000b). 
A.11.3.
 
Example Table Entry 
The following is a typical translation table entry. 
0x000000000000000000010000,ISOC, 
0x000A0100,1000,1<CR><LF> 
This entry indicates: 
 
1000 ISOC protocol tags in the sequence 
 
Each with a handler value of 1 (legacy tag passed through system) 
 
Actual tag IDs range from 
0x000000000000000000010000
 to 
0x0000000000000000000103E7
 
 
Corresponding translated IDs would range from 
0x000A0100
 to 
0x000A04E7