Some tags are encoded with Wiegand data directly on them.  The 3M Toll 
RFID Reader 6204 supports these direct Wiegand encoded tags of the 
following format: 
 
Secure ISOC 
 
ISOB 
 
ISO10374  (if supported by your model of 6204) 
 
Flex (if supported by your model of 6204) 
Because of the security features present on direct Wiegand encoded Secure 
ISOC tags, they can be positively identified, and the Wiegand data encoded 
on the tag is transmitted via the WIM.  For each of the other protocols, some 
C2 variables are used to enable the direct Wiegand feature on a protocol-
by-protocol basis: 
 
modem.protocol.isob.control.wiegand.enabled 
 
modem.protocol.iso10374.control.wiegand.enabled 
 
modem.protocol.flex.control.wiegand.enabled 
When these variables are set to "true", WIMapp will perform the following 
actions when a tag is read: 
1.
1.
1.
1.  The standard tag ID will be looked up in the translation table (described 
above).  If there is an entry matching the tag ID in the translation table, 
the action specified by the translation table entry will be performed. 
2.
2.
2.
2.  If the tag ID is not present in the translation table, and if the direct 
Wiegand feature is enabled via the variables above, then the Wiegand 
data encoded on the tag will be transmitted via the WIM. 
Although the default values are correct for most installations, and should 
not be changed without consulting 3M technical support, it is possible to 
modify the areas in tag memory from which the Wiegand data is extracted 
by changing the following variables: 
 
modem.protocol.isob.control.wiegand.length 
 
modem.protocol.isob.control.wiegand.offset 
 
modem.protocol.iso10374.control.wiegand.length 
 
modem.protocol.iso10374.control.wiegand.offset 
 
modem.protocol.flex.control.wiegand.length 
 
modem.protocol.flex.control.wiegand.offset