Kenwo Industries Limited ARI60 Benutzerhandbuch
Alarm Triggers
When the system is triggered, the siren will sound and the turn signal lights will flash. The
Transceiver’s LCD will display the following messages:
1. If bike is bumped, the LCD displays
icon.
2. If the bike is tilted, the LCD displays icon.
3. If the ignition switch is turned on or tampered with, the LCD displays
Icon.
4. If the perimeter sensor triggers a full alarm cycle, the LCD displays icon.
(Note: The turn signal lights will not flash for a perimeter sensor trigger).
5. With the optional back up system installed, the LCD displays icon if the
(Note: The turn signal lights will not flash for a perimeter sensor trigger).
5. With the optional back up system installed, the LCD displays icon if the
main harness or battery power supply is disconnected. The MCM will still
continue to sound and transmit from its internal power source.
6. The Transceiver will continue to flash the triggered icon until any button is
pressed.
Note: The Transceiver will sound a unique tone to correspond with the triggered sensor
Sensor Memory Display
When the system is disarmed the turn signals will flash to indicate if there has been an
alarm trigger. The lights will flash once to indicate that the system has been disarmed,
additional flashes indicate that the following trigger has occurred:
alarm trigger. The lights will flash once to indicate that the system has been disarmed,
additional flashes indicate that the following trigger has occurred:
1 flash then 1 additional flash = Shock Trigger
1 flash then 2 additional flashes = Tilt Trigger
1 flash then 3 additional flashes = Perimeter Sensor Trigger
1 flash then 5 additional flashes = Ignition Trigger
1 flash then 2 additional flashes = Tilt Trigger
1 flash then 3 additional flashes = Perimeter Sensor Trigger
1 flash then 5 additional flashes = Ignition Trigger
RCS (Range Confirmation Signal)
If the Transceiver is within range of the MCM the LCD displays icon
If the Transceiver does not receive the RCS signal the icon will not appear.
Motorcycle Battery Status
When the voltage on the motorcycle battery drops below 11.2 volts The LCD displays
icon.
Motorcycle Battery Safeguard with “sleep mode”
•
If the optional perimeter sensor is being used and the alarm is armed for more then
10 days the system will automatically disable the perimeter sensor.
10 days the system will automatically disable the perimeter sensor.
•
If the alarm is armed for more than 21 days, the system will automatically disable
the systems receiver. In this mode the transceiver will no longer be able to operate
the system but the system is still armed and protecting the bike.
the systems receiver. In this mode the transceiver will no longer be able to operate
the system but the system is still armed and protecting the bike.
•
To disarm, trigger the alarm, and press the #2 button.
7
Locking the Transceiver’s buttons
To “lock”, press button #4 for 2 sec. The Transceiver will beep and buttons will lock
To “unlock”, press button #4 for 2 sec. The Transceiver will beep and buttons will unlock.
Turning the Transceiver On/Off
To turn “off”, press button #4 for 4 seconds. The Transceiver will beep two times to
indicate that the unit has been turned “off”.
To turn “on”, press button #4 for 4 seconds. The Transceiver will beep two times to
indicate that the unit is turned back “on”.
indicate that the unit is turned back “on”.
Checking Motorcycle Status and Violation Display with Time Stamp
1. Press button #4. The back light and the memory screen will be displayed. If the
alarm was not triggered, all the sensor icons will come on and the # 0 0 will be
displayed.
displayed.
2. If there was an alarm trigger, the last triggered sensor will flash. Press button #4
repeatedly to scroll through all the triggered sensors in the Transceiver’s
memory.
memory.
3. The alternating numeric display shows the current trigger, numbering of triggers
in memory, and the time the trigger occurred. For Example:
[03 05] + [A
8:55] means the tilt sensor was triggered. It was the 3
rd
sensor violated out of a
total of 5 alarm triggers and the event occurred at 8:55am.
4. Press button #3 to exit.
5. To clear memory, press and hold down button #3 for 2 seconds.
Press button
4 once
8
If no alarm triggers in memory, all
sensor icons will be displayed
If the system was trigged, the last triggered
sensor will be displayed
Trigger # Total # of triggers
Time of trigger
Press button 4 repeatedly to
scroll though the trigger memory
Pres button 3 to exit and clear.
Or, press and hold button 3 for 2
seconds to erase memory.
Note: When the Transceiver is in the “Off” mode the clock will still be displayed