ADC Telecommunications Inc. F0694-011 Benutzerhandbuch

Seite von 234
Help Hot Line (U.S. only): 1-800-530-9960
7-31
D-620616-0-20 Rev D
CONFIDENTIAL
Fusion Wideband Installation Procedures
Troubleshooting Expansion Hub LEDs During Installation
• All Expansion Hub 
PORT
 LEDs with RAUs connected should indicate Green/Red. 
This indicates that the RAU is powered on and communication has been estab-
lished.
• The Expansion Hub 
UL STATUS
 LED should be Green.
Table 7-6
Troubleshooting Expansion Hub LEDs During Installation
During
Installation
LED
State
Action
Impact
1.
Expansion 
Hub power 
is On and no 
RAUs are 
connected
POWER
Off
Check AC power; make sure the 
Expansion Hub power-on switch 
is on; replace the Expansion Hub.
The Expansion Hub is not 
powering on.
PORT
LEDs are on but 
didn’t blink through 
all states.
Replace the Expansion Hub.
The Microcontroller is not 
resetting properly; flash 
memory corrupted.
PORT
Flashing Red 
(6 PPM)
Port unusable; replace the Expan-
sion Hub when possible.
Current sensor fault; do not 
use the port.
UL STATUS
Red, after power-up 
blink
Replace the Expansion Hub.
The Expansion Hub laser is 
not operational; no uplink 
between the Expansion Hub 
and Main Hub.
UL STATUS
Red
Check the Main Hub LEDs
Refer to page 7-24, item 2 in 
Table 7-5.
Use AdminBrowser to determine 
the problem.
No communication with 
Main Hub.
DL STATUS
Red
Check the downlink fiber for opti-
cal power; verify that the cables 
are connected to correct ports 
(that is, uplink/downlink)
Check the Main Hub LEDs. Refer 
to page 7-24, item 2 in Table 7-5.
No downlink between the 
Expansion Hub and Main 
Hub.
2.
Expansion 
Hub power 
is On and 
RAUs are 
connected
PORT
Off
Check the CATV cable.
Power is not getting to the 
RAU.
PORT
Flashing Red 
(60 PPM)
Test the CATV cable. If the cable 
tests OK, try another port. If the 
second port’s LEDs are Red/Off, 
replace the RAU. If the second 
RAU doesn’t work; replace the 
Expansion Hub.
Power levels to RAU are not 
correct; communications are 
not established.
If the second port works, flag 
the first port as unusable; 
replace EH when possible.
PORT
Red
Use AdminBrowser to determine 
the problem.
RAU is off-line.