ADC Telecommunications Inc. F0694-011 Benutzerhandbuch

Seite von 234
C-18
InterReach Fusion Wideband Installation, Operation, and Reference Manual
ADC CONFIDENTIAL
D-620616-0-20 Rev D
[E59]/W
Port 3 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than 
one port, replace the Hub, otherwise replace the RAU.
[E60]/W
Port 4 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than 
one port, replace the Hub, otherwise replace the RAU.
[E61]/W
Port 5 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than 
one port, replace the Hub, otherwise replace the RAU.
[E62]/W
Port 6 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than 
one port, replace the Hub, otherwise replace the RAU.
[E63]/W
Port 7 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than 
one port, replace the Hub, otherwise replace the RAU.
[E64]/W
Port 8 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than 
one port, replace the Hub, otherwise replace the RAU.
[E65]/W
Port 1 UL path exceeds maxi-
mum gain.
If the problem is common to more than one port, replace the 
Hub, otherwise check RAU.
[E66]/W
Port 2 UL path exceeds maxi-
mum gain.
If the problem is common to more than one port, replace the 
Hub, otherwise check RAU.
[E67]/W
Port 3 UL path exceeds maxi-
mum gain.
If the problem is common to more than one port, replace the 
Hub, otherwise check RAU.
[E68]/W
Port 4 UL path exceeds maxi-
mum gain.
If the problem is common to more than one port, replace the 
Hub, otherwise check RAU.
[E69]/W
Port 5 UL path exceeds maxi-
mum gain.
If the problem is common to more than one port, replace the 
Hub, otherwise check RAU.
[E70]/W
Port 6 UL path exceeds maxi-
mum gain.
If the problem is common to more than one port, replace the 
Hub, otherwise check RAU.
[E71]/W
Port 7 UL path exceeds maxi-
mum gain.
If problem is common to more than one port, replace the Hub, 
otherwise check RAU.
[E72]/W
Port 8 UL path exceeds maxi-
mum gain.
If the problem is common to more than one port, replace the 
Hub, otherwise check RAU.
[E73]/W
Port 1 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[E74]/W
Port 2 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[E75]/W
Port 3 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[E76]/W
Port 4 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[E77]/W
Port 5 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[E78]/W
Port 6 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[E79]/W
Port 7 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[E80]/W
Port 8 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
Table C-7
Warning/Status Message for Expansion Hubs  (continued)
Message 
Number 
/Default
Description
Reason/Action