Messages for RAUs
In Table C-8, the message number is in the following form:
[Rnn]/X where nn equals the message number, and X equals the default of either Sta-
tus (S) or Warning (W).
Table C-8
Warning/Status Messages for RAUs
Message 
Number
Default
Description
Reason/Action
[R01]/W
Temperature High.
Check RAU location for excessive temperature; check for 
air flow blockage and/or incorrect installation. Move the 
RAU to a cooler environment.
[R02]/W
No communications from Hub.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem persists, replace 
the RAU.
[R03]/W
DL RF path loss is too high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem persists, replace 
the RAU.
[R04]/W
DL RF path exceeds maximum 
gain.
Check the Hub for proper operation; switch the cable con-
nection to a different hub port. If the problem persists, 
replace the RAU.
[R05]/S
DL RF path problem (Band 1).
Unable to complete the DL system end-to-end test, replace 
the RAU when possible.
[R06]/S
DL RF path problem (Band 2).
Unable to complete the DL system end-to-end test, replace 
the RAU when possible.
[R07]/S
DL RF path problem (Band 3).
Unable to complete the DL system end-to-end test, replace 
the RAU when possible.
[R08]/S
System test required.
Run system test.
[R09]/W
Antenna Disconnected.
Check RAU antenna connection; re-run system test.
[R10]/S
UL RF path problem (Band 1).
Unable to complete the UL system end-to-end test, replace 
the RAU when possible.
[R11]/S
UL RF path problem (Band 2).
Unable to complete the UL system end-to-end test, replace 
the RAU when possible.
[R12]/S
UL RF path problem (Band 3).
Unable to complete the UL system end-to-end test, replace 
the RAU when possible.
[R13]/S
Problem detected in the RAU.
Contact ADC Support for more information.
[R14]/S
Problem detected in the RAU.
Contact ADC Support for more information.
[R15]/S
Problem detected in the RAU.
Contact ADC Support for more information.
[R16]/S
Problem detected in the RAU.
Contact ADC Support for more information.
[R17]/S
Antenna disconnected (Band 1).
Check the RAU Band 1 antenna, then rerun the system 
test.
[R18]/S
Antenna disconnected (Band 2).
Check the RAU Band 2 antenna, then rerun the system 
test.
[R19]/S
Hardware Failure (UL FD PLL 
Band 1).
Unable to complete a UL system end-to-end test. Replace 
the RAU when possible.
[R20]/W
TDD signaling tone outside valid 
range (Band 1).
If the Main Hub and Expansion Hub are okay, replace the 
RAU.
[R21]/W
TDD signaling tone outside valid 
range (Band 2).
If the Main Hub and Expansion Hub are okay, replace the 
RAU.