Seite von 234
Faults and Warnings
5-6
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev D
5.4
Faults and Warnings
Both fault and warning conditions are reported to the Fusion Wideband Hub where 
they are stored. Only faults are indicated by the faceplate LEDs.
For more information, refer to Appendix C.
Table 5-3
Remote Access Unit LED States
LED State
Indicates
Off
Off
• The RAU is not receiving DC power.
Green
Green
• The RAU is powered and is not indicating a fault 
condition. Communication with the Fusion 
Wideband Hub is normal; however, the system 
test may need to be performed or a warning con-
dition may exist (use AdminBrowser to deter-
mine this).
Green
Red
• The RAU is indicating a fault or lockout condi-
tion, but communication with the Fusion Wide-
band Hub is normal.
Red
Red
• The RAU is reporting a fault and is not able to 
communicate with the Fusion Wideband Hub
Green (60-ppm)
Green (60-ppm)
• The RAU is reporting a lockout condition, but 
communication with the Fusion Wideband Hub 
is normal.
LINK
ALARM
LINK
ALARM
LINK
ALARM
LINK
ALARM
LINK
ALARM