NOTE: This information is helpful whenever making a technical support call. Click Close and exit the
product information window.
Click Run Diagnostics to run the diagnostic program that will test PC functionality and report the
status. A warning message pops up that the ADSL service will disconnect before performing the
Diagnostic test. If connected to the Internet at this time, disconnect any Dial-up sessions. Click Yes to
begin the diagnostic program or click No to exit diagnostic program.
The Diagnostic program performs a brief hardware check and displays the hardware status.
If the RECSPEED-2021P fails the Diagnostic tests (shown below), then record the test result and
contact customer support.
ADSL bridge - PCI I/O Test 
I90188 chip test 
%
Pass
I90135 Register Test 
I90135 chip test
%
Pass
I90135 Memory Test
I90135 chip test
%
Pass
ADSL Bridge - Loopback  
I90188 Fast datapath
%
Trial 20, Pass 20
…Interleave datapath
%
Trial 20, Pass 20
90135 Utopia Loopback
I90135 Fast datapath
%
Trial 20, Pass 20
…Interleave datapath
%
Trial 20, Pass 20
NOTE: For all loopback tests, both Trial and Pass counts equal 20 for success.
Click Close to exit the Diagnostic program. The modem is disconnected for these diagnostic tests. To
RECSPEED-2021P card is functioning properly, it will automatically reconnect.
Configuring the connection service
To view or edit the ADSL connection service address, Right-click the Diagnostic Tool icon (located on
the taskbar), and select the Configuration option.
The PVC Setup (Permanent Virtual Connection) window displays the connection service address. Click
Close to exit window.
To edit the connection service address, select and enter the VPI and VCI address in the field shown
and click PVC Setting.
To accept a Connection Address that has been changed (and Restart the PC system) click  Yes. Click No
to quit and return to PVC setup window.