Figure 12 shows the Datapath Provisioning menu page, which displays the active network interfaces for the 
installed modules (from both the local and remote TRACER 64x0 units). 
Figure 12.  Datapath Provisioning
> D
ATAPATH
 P
ROVISIONING
 > T
OTAL
 A
CTIVE
 C
HANNELS
Defines the total number of channels active on the installed modules. Specify 
2
4
, or 
8
 total active channels. 
After defining the total number of active channels, specify the actual active channels using the 
C
HANNEL
 
S
ELECTION
 menu.
> D
ATAPATH
 P
ROVISIONING
 > M
ODULE
 1/M
ODULE
 2 C
HANNELS
(Read Only) Displays the total number of active channels on the installed module.
> D
ATAPATH
 P
ROVISIONING
 > C
HANNEL
 S
ELECTION
Defines the active channels (
A
B
C
D
) on each installed T1 module or the bandwidth dedicated to the Quad 
Ethernet Switch module (in 2 Mbps steps). To activate a channel, press <Enter> and use the spacebar or 
arrow keys to cycle through the available channel combinations until the desired combination displays. Press 
<Enter> again to make the channel combination change. If the specified channel selection is not valid, the 
TRACER 64x0 automatically corrects the configuration and populates the field with a valid selection.
The number of active channels and the channel configuration on both the local and remote 
systems must match for the RF link to function properly. A discrepancy between the systems 
can result in unpredictable operation.
The number of active channels and the channel configuration on both the local and remote 
systems must match for the RF link to function properly. A discrepancy between the systems 
can result in unpredictable operation.