CTK03 ComfortNet™ Communicating Thermostat
17
I/O-CHTSTAT03  69-2688—01
Heat Pump/Air Conditioner User Menus
Configuration (CONFIG)
Sub-menu Item
Indication (for Display Only; not User Modifiable)
AC Tonnage (TONS)
Displays the air conditioning tonnage; applies to AC and HP.
Number of AC Stages 
(CL STG)
Displays the number of air conditioning stages; applies to AC and HP.
Number of HP Stages 
(HT STG)
Displays the number of heat pump stages; applies to HP only.
Diagnostics (DIAG)
Sub-menu Item
Indication/User Modifiable Options
Comments
Fault 1 (FAULT #1)
Most recent AC/HP fault
For display only
Fault 2 (FAULT #2)
Next most recent AC/HP fault
For display only
Fault 3 (FAULT #3)
Next most recent AC/HP fault
For display only
Fault 4 (FAULT #4)
Next most recent AC/HP fault
For display only
Fault 5 (FAULT #5)
Next most recent AC/HP fault
For display only
Fault 6 (FAULT #6)
Least recent AC/HP fault
For display only
Clear Fault History 
(CLEAR)
NO or YES
Selecting “YES” clears the fault 
history
NOTE: Consecutively repeated faults are shown a maximum of 3 times.
Identification (IDENT)
Sub-menu Item
Indication (for Display Only; not User Modifiable)
Model Number (MOD NUM) Displays the air conditioner or heat pump model number
Serial Number (SER NUM) Displays the air conditioner or heat pump serial number 
(Optional)
Software (SOFTWARE)
Displays application software revision
Sensors (SENSORS)
Sub-menu Item
Indication/User 
Modifiable Options
Comments
Outdoor Air Temperature 
(AIR TMP)
Displays the outdoor air 
temperature
Sensor may or may not be available on 
an air conditioner. Check air conditioner 
instructions for details.
Outdoor Coil Temperature 
(COIL TMP)
Displays the outdoor coil 
temperature
Applies for heat pump operation.