Binsfeld Engineering Inc TX10K-LP Benutzerhandbuch

Seite von 44
- 37 - 
 
B3: Single Grid (1/4 Bridge) 
Step 1:  Calculate Full Scale Strain, 
ε
FS
  (inches/inch)  that 
corresponds to the maximum system output of 10.0V. 
 
 
Using the values listed in the table below, this equation reduces to: 
 
 
 
Legend of Terms 
ε
FS
 
Full Scale Strain (inches/inch; 10
-6
 inches/inch =  
1 microstrain) 
GF 
Gage Factor (specified on strain gage package) 
G
XMT
 
Telemetry Transmitter Gain (user configurable, typical 
is 4000 for ±2000 microstrain range) 
TX
const
 
Transmitter constant = 2.5 volts 
V
FS
 
Full Scale Output of System = 10 volts 
 
 
Example: 
GF (gage factor from gage package) = 2.045 
 
G
XMT
 (TX10K gain setting) = 4000 
 
 
    
   (16)  
ε
FS
  =  
 
         = 1956 x 10
-6
 inches/inch 
         (2.045)(4000) 
 
 
 
so 10 V output from the RX10K indicates 1956 microstrain or 196 
microstrain/volt. 
 
For information on output scaling and calibration, see section B1. 
 
            (V
FS
)(4) 
          =  
ε
FS
 
     (TX
const
)(GF)(G
XMT
 
 
    
      (16) 
          =  
ε
FS
 
 (GF)(G
XMT