Senstar Corporation 24000 Benutzerhandbuch
CUbYUc!& 9^cdQ\\QdY_^Q^T_`UbQdY_^WeYTUQ!
a
Specifications
Ge
ne
ra
l
Voltage requirements
•
11 - 15 VDC
Current requirements
•
100 mA total per system (maximum)
Dimensions
•
width - 15 cm (6 in.)
•
depth - 9 cm (3.5 in.)
•
height - 32 cm (12.5 in.)
Weight
•
unpacked - 2.27 kg (5 lbs.)
•
packed - 3.6 kg (8 lbs.)
Model 16001
•
standard unit for commercial applications
Model 16004
•
High reliability unit for high security applications - Fully
documented and traceable acceptance test program. Fully tested
(burned in) at high and low temperature extremes.
documented and traceable acceptance test program. Fully tested
(burned in) at high and low temperature extremes.
Tra
ns
m
itt
er
Operating voltage & current •
11 - 15 VDC, 70 mA maximum
Microwave carrier frequency •
10.525 GHz
± 25 MHz
Microwave output
•
less than 0.25 volts per meter, maximum at 30 m (98 ft.)
Operating range
•
ingress/egress: 244 m (800 ft.)
Separation distance
•
transmitter/receiver - high security 100 m (328 ft.)
Antenna pattern (adjustable)
•
short range - 24º
•
medium range - 16º
•
long range - 11º
Antenna polarization
•
E-plane, vertical (E-plane horizontal - optional)
Modulation
•
type: square wave, type A2
•
channels: 6 field selectable
Tamper circuit contact rating •
1 A, 28 VDC
Operating temperature
•
-40º to +70ºC (-40º to +158º F) - Model 16001