Senstar Corporation 24000 User Manual

Page of 46
CUbYUc!&   9^cdQ\\QdY_^Q^T_`UbQdY_^WeYTU“““Q!
a
Specifications
Ge
ne
ra
l
Voltage requirements
11 - 15 VDC
Current requirements
100 mA total per system (maximum)
Dimensions
width - 15 cm (6 in.)
depth - 9 cm (3.5 in.)
height - 32 cm (12.5 in.)
Weight
unpacked - 2.27 kg (5 lbs.)
packed - 3.6 kg (8 lbs.)
Model 16001
standard unit for commercial applications
Model 16004
High reliability unit for high security applications - Fully 
documented and traceable acceptance test program. Fully tested 
(burned in) at high and low temperature extremes.
Tra
ns
m
itt
er
Operating voltage & current 
11 - 15 VDC, 70 mA maximum
Microwave carrier frequency 
10.525 GHz 
± 25 MHz
Microwave output
less than 0.25 volts per meter, maximum at 30 m (98 ft.)
Operating range
ingress/egress: 244 m (800 ft.)
Separation distance
transmitter/receiver - high security 100 m (328 ft.) 
Antenna pattern (adjustable)
short range - 24º
medium range - 16º
long range - 11º
Antenna polarization
E-plane, vertical (E-plane horizontal - optional)
Modulation
type: square wave, type A2
channels: 6 field selectable
Tamper circuit contact rating 
1 A, 28 VDC
Operating temperature
-40º to +70ºC (-40º to +158º F) - Model 16001