TX Code Domain Power/Noise Floor Acceptance Test
68P64115A18–1
Mar 2003
1X SC 4812T Lite BTS Optimization/ATP Software Release R2.16.1.x
DRAFT
4-25
Code Domain Power/Noise Floor Test
Follow the steps in Table 4-11 to verify the Code Domain Power/Noise
floor of each selected BBX carrier keyed up at a specific frequency.
Table 4-11: Test Code Domain Power/Noise Floor
Step
Action
1
Set up the test equipment for TX acceptance tests per Table 4-3.
2
Select the BBXs and MCCs to be tested.
3
Click on Tests in the BTS menu bar, and select TX > Code Domain Power... from the pull–down
menus.
4
Select the appropriate carrier(s) and sector(s) (carrier-bts#-sector#-carrier#) from those displayed in the
Channels/Carrier pick list.
NOTE
To select multiple items, hold down the Shift or Ctrl key while clicking on pick list items to select
multiple carrier(s)–sector(s).
5
Verify that the correct channel number for the selected carrier is shown in the Carrier # Channels
box. If it is not, obtain the latest bts–#.cdf (or bts–#.necf) and cbsc–#.cdf files from the CBSC.
NOTE
If necessary, the correct channel number may be manually entered into the Carrier # Channels box.
6
If at least one MCC was selected in Step 3, select the appropriate transfer rate (1 = 9600, 3 = 9600 1X)
from the drop–down list in the Rate Set box.
NOTE
The Rate Set selection of is only available if 1X cards are selected for the test.
7
Click OK to display a status  bar followed by a Directions pop-up window.
8
Follow the cable connection directions as they are displayed, and click the Continue button to begin
testing.
– As the ATP process is completed, results will be displayed in a status report window.
9
Click the Save Results or Dismiss button.
NOTE
If Dismiss is used, the test results will not be saved in the test report file.
 
4