Echelon Corporation 70101-R003 Benutzerhandbuch

Seite von 81
34 
Pole Mount Installation 
 
Table 3. Internal Audio Indicator Sound Patterns 
Sound Pattern 
Description 
On (ms) 
Off (ms) 
Repeat 
1000 
ECN boot process successful 
System Manager is now running 
4000 
ECN boot process failed 
1000 
500 
WAN connection to cell tower successful  
4000 
200 
WAN connection to cell tower failed 
1000 
500 
Connection to System Software successfully 
established 
4000 
200 
Connection to System Software failed 
As the table shows, a successful installation should include several 1 second 
sound bursts, some with a repeated pattern (1 s on, 0.5 s off) to indicate 
successful network connections. If you receive a 4 s sound burst, the ECN boot 
process failed.  If you receive the repeated pattern (4 s on, 0.2 s off), a network 
connection failed; check the network cable connection and verify that the network 
is operational. 
After installation is verified successful, use the COS Web page interface for the 
ECN to verify additional functionality.  You might also want use the command-
line interface to disable the internal audio indicator so that subsequent resets or 
power events do not cause the audio indicator to output its audio indicator 
patterns.  You can also change the audio indicator patterns by modifying the 
controller configurable file (CCF); see the COS User’s Guide for information 
about modifying the audio indicator patterns.