Image Sensing Systems Inc. RTMS-X3 Benutzerhandbuch
RTMS
User Manual
Issue 3.2
32
EIS Electronic Integrated Systems Inc.
RTMS STAT. MESSAGES ZONE: 1 2 3 4 5 6 7 8
SPEED IN Km/h. Occupancy 6 ft loop normalized.
11 03 2003 19:32:02
MESSAGE NO. 6 VOLUME: 5 8 19 17 6 9 11 16
LONG VEH: 0 0 0 0 1 2 2 0
STATION ID. 8 OCCUPANCY: 5 7 18 13 8 14 15 13
MID SIZE: 1 0 1 0 0 0 1 1
XLONG VEH: 0 0 0 0 1 0 0 0
FWDLK SPEED ? SIDEFRD SPD: 81 102 124 112 77 103 128 125 Dir. 128 V. 125 H. 80
11 03 2003 19:32:32
MESSAGE NO. 7 VOLUME: 6 8 10 11 11 12 14 17
LONG VEH: 0 0 0 0 0 3 2 0
STATION ID. 8 OCCUPANCY: 4 7 8 8 9 19 20 11
MID SIZE: 0 0 0 0 0 1 0 0
XLONG VEH: 0 0 0 0 0 0 1 0
FWDLK SPEED ? SIDEFRD SPD: 94 102 126 120 80 102 119 118 Dir. 128 V. 125 H. 80
11 03 2003 19:33:02
MESSAGE NO. 8 VOLUME: 6 7 16 12 6 11 11 13
LONG VEH: 0 0 0 0 0 0 0 0
STATION ID. 8 OCCUPANCY: 4 5 14 9 5 11 9 7
MID SIZE: 0 0 0 0 1 0 0 0
XLONG VEH: 0 0 0 0 0 0 0 0
FWDLK SPEED ? SIDEFRD SPD: 89 111 118 109 79 100 124 125 Dir. 128 V. 125 H. 80
SPEED IN Km/h. Occupancy 6 ft loop normalized.
11 03 2003 19:32:02
MESSAGE NO. 6 VOLUME: 5 8 19 17 6 9 11 16
LONG VEH: 0 0 0 0 1 2 2 0
STATION ID. 8 OCCUPANCY: 5 7 18 13 8 14 15 13
MID SIZE: 1 0 1 0 0 0 1 1
XLONG VEH: 0 0 0 0 1 0 0 0
FWDLK SPEED ? SIDEFRD SPD: 81 102 124 112 77 103 128 125 Dir. 128 V. 125 H. 80
11 03 2003 19:32:32
MESSAGE NO. 7 VOLUME: 6 8 10 11 11 12 14 17
LONG VEH: 0 0 0 0 0 3 2 0
STATION ID. 8 OCCUPANCY: 4 7 8 8 9 19 20 11
MID SIZE: 0 0 0 0 0 1 0 0
XLONG VEH: 0 0 0 0 0 0 1 0
FWDLK SPEED ? SIDEFRD SPD: 94 102 126 120 80 102 119 118 Dir. 128 V. 125 H. 80
11 03 2003 19:33:02
MESSAGE NO. 8 VOLUME: 6 7 16 12 6 11 11 13
LONG VEH: 0 0 0 0 0 0 0 0
STATION ID. 8 OCCUPANCY: 4 5 14 9 5 11 9 7
MID SIZE: 0 0 0 0 1 0 0 0
XLONG VEH: 0 0 0 0 0 0 0 0
FWDLK SPEED ? SIDEFRD SPD: 89 111 118 109 79 100 124 125 Dir. 128 V. 125 H. 80
Fig 18. Sample Recorded File Format
Self-Test diagnostic
The RTMS sensor can be tested any time to confirm that it is in working order. Select Self Test
from the TOOLS
from the TOOLS
window. The PC sends a Self-test command to the sensor. During the 20
seconds required by the RTMS to complete the test, a progress bar is displayed, ending with a
display of the diagnostic results, including the RTMS firmware revision when the test is
completed. Self-Test should be performed with the sensor monitoring real traffic.
display of the diagnostic results, including the RTMS firmware revision when the test is
completed. Self-Test should be performed with the sensor monitoring real traffic.
Support for Other Languages
The RTMS Setup Utility program allows replacement of the default English button legends and
menu labels to other languages.
A Notepad file “Rtmslng.txt” (partially shown below), is included in the same folder with the
“WinRtms.exe” program. Its default labels may be altered. To adapt the operation to your
language, edit this text file, replacing English legends by text in your language, after “=” using a
character set provided by your PC. Use character “&” to identify the next character as keyboard
shortcut.
menu labels to other languages.
A Notepad file “Rtmslng.txt” (partially shown below), is included in the same folder with the
“WinRtms.exe” program. Its default labels may be altered. To adapt the operation to your
language, edit this text file, replacing English legends by text in your language, after “=” using a
character set provided by your PC. Use character “&” to identify the next character as keyboard
shortcut.
[MainForm]
FormTitle=RTMS Setup utility ver.
MenuInfo=&Info
MenuHelp=Press F1 for help
ButtonMode=&MODE
ButtonSensitivity=&SENSITIVITY
ButtonZones=&ZONES
ButtonFineTune=&FINETUNE
ButtonPeriod=&PERIOD
ButtonVerify=&VERIFY
FormTitle=RTMS Setup utility ver.
MenuInfo=&Info
MenuHelp=Press F1 for help
ButtonMode=&MODE
ButtonSensitivity=&SENSITIVITY
ButtonZones=&ZONES
ButtonFineTune=&FINETUNE
ButtonPeriod=&PERIOD
ButtonVerify=&VERIFY
ButtonSpeedCalibration=SPEED &CALIB
ButtonIDnumber=&ID NUMBER
ButtonData=&DATA
ButtonTools=&TOOLS
ButtonAdvanced=&ADVANCED
ButtonFile=FIL&E
ButtonIDnumber=&ID NUMBER
ButtonData=&DATA
ButtonTools=&TOOLS
ButtonAdvanced=&ADVANCED
ButtonFile=FIL&E
Power voltage (x 10), i.e. 12.5V
Direction (Applicable to FwdLk
mode, 0 =In, 128= Out )
mode, 0 =In, 128= Out )
Diagnostic byte.
Consult EIS if second
digit is not equal to “0”
Consult EIS if second
digit is not equal to “0”