Image Sensing Systems Inc. SX300AN Benutzerhandbuch
Chapter 6:
Messages
RTMS Sx-300 User Guide
©2014 Image Sensing Systems Inc.
6-2
Message:
‘Per Vehicle ON’ is active. In order for ‘Per Vehicle’ data to be collected when in
Polled mode, the ‘Store Into Memory’ option should be selected.
Polled mode, the ‘Store Into Memory’ option should be selected.
Description:
This warning message indicates that data collection for Per Vehicle cannot occur when
the Autoscope RTMS Sx-300 sensor is in Polled mode unless the Store Into Memory
option is selected.
the Autoscope RTMS Sx-300 sensor is in Polled mode unless the Store Into Memory
option is selected.
Suggested Action:
Click OK. Data collection for Per Vehicle is disabled. To enable data collection for
Per Vehicle, do one of the following.
Per Vehicle, do one of the following.
1. Change the mode to STAT or Normal (see
).
2. Turn on the Store Into Memory option (see
Message:
The sensor you have selected is not compatible with this version of the setup
utility. Please install the G4 setup utility to configure this sensor.
utility. Please install the G4 setup utility to configure this sensor.
Description:
You attempted to configure an RTMS G4 sensor but the setup utility for this type of
sensor is not installed on your computer.
sensor is not installed on your computer.
Suggested Action:
Install the latest version of the setup utility for this type of sensor. For more
information, contact your sales or service representative.
information, contact your sales or service representative.
Message:
There is at least one port working in Polled mode. In order for ‘Per Vehicle’ data
to be collected, the ‘Store Into Memory’ option should be selected.
to be collected, the ‘Store Into Memory’ option should be selected.
Description:
This warning message indicates that data collection for Per Vehicle cannot occur when
the Autoscope RTMS Sx-300 sensor is in Polled mode unless the Store Into Memory
option is selected.
the Autoscope RTMS Sx-300 sensor is in Polled mode unless the Store Into Memory
option is selected.
Suggested Action:
Click OK. To not do data collection for Per Vehicle, select Per Vehicle OFF. To enable
data collection for Per Vehicle, do one of the following.
data collection for Per Vehicle, do one of the following.
1. Change the mode to STAT or Normal (see
).
2. Turn on the Store Into Memory option (see