Image Sensing Systems Inc. SX300AN Benutzerhandbuch

Seite von 203
Traffic Data Files
RTMS Sx-300 User Guide
©2014 Image Sensing Systems Inc.
C-2
4
Message No. — The message number. It will go from 0 to 255. On the 
256th message it will be message 0 again.
Volume — This is the total volume for each zone.
** Note: To calculate “Small” classification, add up the individual 
classifications listed below and subtract that number from the total 
volume.
5
Volume counts for each zone for the Regular Class size.
6
Volume counts for each zone for the Medium Class size.
7
Volume counts for each zone for the Large Class size.
8
Volume counts for each zone for the Truck Class size.
9
Volume counts for each zone for the Extra Large Class size.
10
Station ID — This is the sensor ID. Set in Manual Settings -> Sensor ID
Occupancy — The occupancy value for each zone.
11
FWDLK SPEED — Not used. 
SideFrd SPD — The is the speed value for each zone when using the 
Side-Fired or Midblock modes. 
Dir — This is the direction value when using the forward looking mode 
(this value is sometimes needed when troubleshooting with Technical 
Support personnel). 
V — This is the voltage reading at the Autoscope RTMS Sx-300. This is a 
real number reported as a whole number. For example 239 equals 23.9 V. 
The maximum value that can be shown is 25.5.
H — This is a Health Byte value. This is only used for troubleshooting 
purposes with Technical Support personnel.
12
The Gap or Headway values for each zone.
Table C-1: File Format Description (Cont’d)
Line
Description