2.3.1.18  Set target modulation conductance register 
This command allows switching to a different modulation conductance register.  On startup, 
modulation conductance register 0 is used. 
When more than one antenna is used, it may be necessary to use different modulation 
conductance values for different antennas.  Switching registers does not require knowledge of the 
actual values used. 
Ensure that Modulation Conductance registers 1-3 are initialized before using this feature. 
Command 
Command 
Data 
om 
Target modulation conductance register (1 byte)  Valid range 00h – 03h 
 
Answer 
Answer 
Description 
Data (2 bytes) 
Target modulation conductance register (1 byte);  register value (1 byte) 
‘R’ 
Error:  Out of range  [selected register is out of range] 
 
2.3.1.19  Reread all registers 
This command rereads and applies all register settings. 
Command 
Command 
Data 
Ox none 
 
Answer 
Answer 
Description 
Data (3 bytes) 
'X' + new protocol + new baud rate 
 
Example 
Command 
Description 
Ox Answer: 
X0106 
binary protocol and 460800 baud active 
New protocol 
00h means ASCII and 01h means binary protocol. 
New baud rate 
Values of 00h-06h are valid. For baud rate values refer to 