2.3.1.18 Set target modulation conductance register
This command allows switching to a different modulation conductance register. On startup,
modulation conductance register 0 is used.
modulation conductance register 0 is used.
When more than one antenna is used, it may be necessary to use different modulation
conductance values for different antennas. Switching registers does not require knowledge of the
actual values used.
conductance values for different antennas. Switching registers does not require knowledge of the
actual values used.
Ensure that Modulation Conductance registers 1-3 are initialized before using this feature.
Command
Command
Data
om
Target modulation conductance register (1 byte) Valid range 00h – 03h
Answer
Answer
Description
Data (2 bytes)
Target modulation conductance register (1 byte); register value (1 byte)
‘R’
Error: Out of range [selected register is out of range]
2.3.1.19 Reread all registers
This command rereads and applies all register settings.
Command
Command
Data
Ox none
Answer
Answer
Description
Data (3 bytes)
'X' + new protocol + new baud rate
Example
Command
Description
Ox Answer:
X0106
binary protocol and 460800 baud active
New protocol
00h means ASCII and 01h means binary protocol.
New baud rate
Values of 00h-06h are valid. For baud rate values refer to
August 2010
Page 57 of 144