1 4      CrossCheck CDPD Mobile Unit Manual
Table 2.2 lists the MDT connector pinout.
2.4
Inspecting and Unpacking the Shipment
The CrossCheck CDPD may be shipped in one or more cartons, 
depending on the number of units and the options ordered with the 
shipment. Before opening the shipping containers, inspect the cartons 
for punctures or damage and immediately report any damage to the 
shipping carrier. Then open the shipping cartons individually and 
check their contents against the packing slip.
Table 2.2
MDT Connector Pinout
Pin
Signal
Connection
1
DCD
Output: Carrier Detect
2
RxD
Output: Serial Data
3
TxD
Input: Serial Data
4
DTR
Input: Data Terminal Ready
5
GND
Ground
6
DSR
Output: Data Set Ready
7
RTS
Input: Request to Send
8
CTS
Output: Clear to Send
9
PWR
Output: 8.5 VCD @ 200 mA max. 
(Interpreted as RS-232 hi-level.)