Trimble Inc. CCKCDPD Benutzerhandbuch

Seite von 88
CrossCheck CDPD Mobile Unit Manual     1 9
Installation     2
Direct Connection through Mounting Screws
To mount the CrossCheck CDPD Mobile Unit on a metal surface that 
is permanently attached to the vehicle chassis (for example, the base 
of the trunk, or a mounting plate that is permanently attached to the 
chassis using metal screws):
1.
Fasten down the CrossCheck CDPD using metal screws driven 
through the metal tabs on the sides of the unit.
2.
Use star washers to ensure a reliable electrical contact to the 
metal tabs.
3.
Make sure the screws are tight, and that they make contact both 
with the metal on the CrossCheck CDPD and with the vehicle 
chassis.
Note – If this direct connection through mounting screws method is 
used for chassis connection, then the chassis ground (pin 3 on the 
power and discrete I/O connector) on the CrossCheck CDPD should 
be left unconnected.
Connection through the Chassis Ground Wire
If the CrossCheck CDPD cannot be mounted directly on a metal 
surface that is attached to the vehicle, then use the chassis ground wire 
(pin 3 on the power and discrete I/O connector) to make electrical 
contact to the vehicle chassis:
1.
Use a wire with gauge of at least 18 AWG to connect the 
CrossCheck CDPD power connector to the vehicle chassis.
2.
Use a metal screw with a star washer to ensure a reliable 
electrical contact to the vehicle chassis.
3.
Keep the wire length as short as possible by selecting a 
connection point in the vehicle chassis that is close to the 
CrossCheck CDPD.