4 2      CrossCheck CDPD Mobile Unit Manual
2.9.8
 Outputs (XP0 to XP2)
The CrossCheck CDPD features three discrete outputs (XP0–XP2) for 
driving external devices such as relays. 
When inactive (use state), the discrete outputs are tied to vehicle 
battery voltage (nominally 12 VDC) through a 15 kOhm 
resistor.
When active, the outputs are shorted to ground through a 
bipolar junction transistor. In the active (low) state, the outputs 
can sink up to 200 mA. 
Figure 2.21 shows a diagram of a discrete output.
Figure 2.21
Output Circuit Diagram
Output Inactive:
15 kOhms through V
vehicle-battery
Output Active:
Tied to ground through a saturated bipolar 
junction transistor, V
out
 1.5 VDC at 
200 mA; V
out
 < 0.5 VDC at 
10 mA 
Output Protection:
Protected against direct shorts to ground 
Output Sink Current 
Capability
Up to 200 mA
15K
36V
0.01µF
0.2A
470pf
Output
Vbatt