Trimble Inc. CCKCDPD Benutzerhandbuch

Seite von 88
CrossCheck CDPD Mobile Unit Manual     4 7
Installation     2
Figure 2.24 illustrates the Power Management connections.
Figure 2.24
Power Management Connections
To install the power cable for use with the Power Management feature:
1.
Connect the primary power line to a nonswitched/continuous 
source of DC power, such as the vehicle’s battery. 
2.
Connect the ignition-sense line to ignition-switched battery 
power so that this line is active when the ignition is on. 
Power and I/O Cable
Vbatt.
Batt. GND
Chassis GND
GND
IGN
IP3
IP2
XP2
IP1
XP1
IP0
XP0
Pulse 0
Pulse 1
Pulse 2
8V Aux
2A @ 250V
Blade Type
To CrossCheck
CDPD
Red
Black
Green
White