Wi Lan Inc EB02 Benutzerhandbuch

Seite von 190
Radio Module Configuration
APR 2001 Rev 03
83
➧ 
To set remote unit RF group
1.
From the Main Menu, select RF Module Configuration and press 
Enter
. The g menu is displayed.
2.
Select Remote Unit RF Group and press 
Enter
. The data field highlights.
3.
In the Remote Unit RF Group entry field, type the RF group number, using the following table as a guide.
4.
Press 
Enter
. The new setting is displayed in the "New" column.
5.
Select Reboot New RF Configuration and press 
Enter
. The unit reboots and the AWE 120-58 
Login menu is displayed. The unit now runs using the "Current" remote unit RF group for the amount 
of time specified by Config Test Minutes.
6.
To save the current setting(s) to FLASH, log in, go to the Main Menu, and select Radio Module 
Configuration,
 Save Current Config to Flash. See 
7.
Press 
Esc
 to exit to the Main Menu.
                             Radio Module Configuration
                                      New         Current        Flash
Station Type                      Remote Unit   Remote Unit   Remote Unit
Station Rank (1-1000)             1             1             1
Center Frequency (57410-58338)    5.7874 GHz    5.7874 GHz    5.7874 GHz
Security Password 1  (Hex)        1             1             1
Security Password 2  (Hex)        10            10            10
Security Password 3  (Hex)        100           100           100
Security Password 4  (Hex)        1000          1000          1000
Security Password 5  (Hex)        10000         10000         10000
Scrambling Code      (Hex)        0             0             0
Acquisition Code     (0-15)       1             1             1
Config Test Minutes  (1-120)      30            30            30
Tx Power Level Adjust             0 dB          0 dB          0 dB
Base Station Only Parameters
Repeater Mode                     off           off           off
System Symmetry Type              Asymmetric    Asymmetric    Asymmetric
Dynamic Polling Level (1-100)     1             1             1
Remote Station Only Parameters
Remote Unit RF Group (0-63)    -> 0             0             0
Reboot New RF configuration       Press Enter to Execute
Save Current Config to Flash      Press Enter to Execute