Wi Lan Inc EB03 Benutzerhandbuch

Seite von 190
Installation
22
 AWE 120-24 Installation & Configuration Guide
Testing a Basic RF Link
When both the base station and remote unit can receive and transmit data to each another (indicated by 
orange Air LEDs on both units), a basic RF link is established. You can now test the link with Link Monitor. 
Link Monitor tests a link by sending and receiving test data over a link, in both directions, at the same time. 
For information about testing a link in the receive or transmit direction only, see 
➧ 
To test the RF link
1.
Connect the test PC to the Serial port of the base station or remote unit. See 
2.
Log in to the unit and go to the Main Menu.
3.
Select RF Station Configuration and press 
Enter
The RF Station Configuration window is 
displayed.
 • Select Operating Mode. Press the arrow keys to select Normal mode.
 • Select RF Transmit Status. Select unblocked.
 • Select Link Monitor Remote Station Rank. Enter the rank of the unit that you want to 
link test. (The rank is the identification number of the unit. The rank of a remote can be any num-
ber from 1 – 1000. The rank number of the the base station is always 0. See 
.
)
 •  Select Link Monitor/Output Power. Choose Normal
 •  Select Signal Margin and enter an initial value of 6.
 •  Select Link Monitor Period. Enter a link monitor period of 1. (A value of 1 means that 50% 
of available data packets will carry test data. The higher the period number, the fewer the number 
                     RF Station Configuration
    Operating Mode                        -> Normal Mode
    RF Transmit Status                       unblocked
    Link Monitor Period (0=OFF, 1-10000)     0
    Test Mode Timer Minutes (1-1000)         5
    Base Station Only Parameters
    Maximum Remote Distance                  5 Km
    Link Monitor Remote Station Rank         1
    Remote Station Only Parameters
    Throttle Enable                          off
    Throttle Level (1-100)                   1
    Link Monitor/Output Power                Normal
    User Output Power Adjust Ceiling         -5  dB
    Signal Margin (6-31) dB                   6
    Current Output Power Level Adjust        -21