12. View the link statistics. From the Main Menu select Link Monitor Display and press 
Enter
. The RF 
Link Monitor Statistics window is displayed.
13. Check for BER = 0.0E+00 and Corr Power between 15 – 50 dB
If the Corr Power is <15 dB the 
receive signal is probably too weak. If the power is >55 dB the receiving unit is probably saturated. See 
, page 103 for more information about Link Monitor Statistics.
If you have problems, ensure that the unit is configured to its basic default settings (see 
, page 101) and reconfigure the unit or contact Wi-LAN customer support.
14. When you finish viewing link monitor statistics, disable Link Monitor to remove the test overhead data 
from the RF link. Select RF Station Configuration from the Main Menu and press 
Enter
. The  RF 
Station Configuration menu is displayed.
15. Select Link Monitor Period and press 
Enter
. The field is highlighted.
16. Type 0 in the field and press 
Enter
. The link monitor test ends.
17. Press 
Esc
 to exit.
Note: When testing, it is possible to run the link monitor in both directions over one link by enabling link 
monitor on the base and the remote at the same time. This situation should be avoided during normal 
operation because it causes needless overhead.
Performing Transmit and Receive Tests
When performing transmit or receive tests, one unit is set up to operate in Transmit Test mode and the other 
unit is set up to operate in Receive Test mode. The transmitting unit sends packets of known data to the 
receiving unit. The receiving unit analyzes the data and displays link statistics on the PC connected to the 
Serial port.
➧ 
To set up the transmit unit
1.
Connect a PC to the Serial port of the unit.
2.
Log in to the unit and go to the Main Menu.
3.
From the Main Menu, select RF Station Configuration and press 
Enter
The RF Station 
Configuration menu is displayed.
4.
Select Operating Mode and press 
Enter
. The field highlights.
5.
Select Transmit Test and press 
Enter
. The Mode LED on the unit is red, indicating that the unit is 
transmitting.
                      RF Link Monitor Statistics
    Link Monitor Rank                    1
    Base to Remote BER                   0.0E+00
    Remote to Base BER                   0.0E+00
    Missed Packet Count                  0
    Base to Remote Env Power             27
    Base to Remote Corr Power            28
    Remote to Base Env Power             29
    Remote to Base Corr Power            30