CALAMP WIRELESS NETWORKS INC. 1409123000 Benutzerhandbuch

Seite von 52
    
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
           CONFIGURATION 
 
001-9193-001 Version 2   
 
 
 
 
 
Page 45 of 52  
 
 
  
 
 
                Sentry 4G
 
TM
 User 
Manual 
 
5.9 I/O Settings 
The Sentry 4G router supports the following I/Os:  
 
Ignition Sense 
 
One external digital alarm  
 
See Table 5 for pinout. 
 
 
 
J4 
Pin 
Signal 
I/O 
Description / specification 
Ignition
Sense 
Input to 
Sentry 4G 
Standard ignition-on signal 1. Pin 1 is the left most pin when looking 
directly at the front panel. 
Maximum voltage above which Ignition Sense will be detected as 
ignition asserted = 9.0V;  
Minimum voltage below which Ignition Sense will be detected as 
ignition de-asserted = 5.7V. 
External 
Alarm 
Input to 
Sentry 4G 
Active low signal. To trigger an alarm, short this signal to V
IN-
 using 
a low impedance path (100-Ohm max)  
For 200ms minimum. Otherwise, leave open or connect to V
IN+.  
This 
signal can also be driven from a 5V/3.3V TTL/LVTTL or CMOS circuit. 
 
 
Table 5 - I/O Signal Pinout