VTech Telecommunications Ltd 80-0720-00 Benutzerhandbuch

Seite von 2
Motion detection
The Motion Sensor detects motion with one-minute cool off time. Once motion is detected, the 
sensor will start detecting motion again only after one minute. 
Pet-Immune Intrusion Detection detects the major motion of a person over several steps of 
walking, while 
Occupancy Detection detects the relatively minor motions of sedentary occupants 
such as adults, babies, and pets in a room. Pet-Immune Intrusion Detection is designed to 
discern humans from small animals, so that the sensor can report movement of persons in 
locked/unoccupied areas, while allowing pets to roam about such areas without being reported.
The sensor detects motion horizontally within a 90° angle, and vertically within a 48° angle. The 
detection area covers up to 
20 X 20 feet. For the most complete coverage of a rectangular room, it 
is recommended to mount the sensor in a corner of the room.
The Motion Sensor should be placed facing away from large windows. To provide the best 
detection performance, it is recommended to mount the Motion Sensor with its wall mount bracket 
on the corner or the wall, within one of the two height ranges:
NOTE
The numerical values in the illustrations are for conceptual reference only. The actual angles and distances 
may vary upon the change in the mounted height of the sensor.
Check the sensor before use
1.  Place the sensor about 
3.3 feet (1 meter) 
from the ULE compatible product.
2.  Press and hold the 
PAIR button on the 
Motion Sensor for 3 seconds.
3.  Release and immediately press the 
PAIR 
button again to enter the test mode until 
the green LED is steadily on. The test 
mode will last for 5 minutes.
4.  Walk across the area in front of the sensor.
The green LED on the sensor will flash.
You will receive notifications at your 
ULE compatible product. Refer to the 
Installation guide or user’s manual of 
your ULE compatible product for the 
sensor alerts.
NOTES
Make sure you have done step 3 right after  
step 2. Otherwise, the sensor will enter the 
pairing mode.
In the test mode, once motion is detected, the 
sensor will only start to detect motion again after 
5 seconds.
In the normal mode, once motion is detected, 
the sensor will only start to detect motion again 
after one minute. When you have received alerts 
already, you will only receive alerts again for 
motion detected after one minute.

Test the sensor signal strength
You can mount the Motion Sensor at a 
location where family members or unwanted 
visitors are likely to be coming and going.
1.  Take the sensor to the desired mounting 
location and then, temporarily mount it 
at the desired height (Refer to 
Motion 
detection section). Use adhesive tape to 
hold the bracket temporarily in place.
If your ULE compatible product has a 
signal checking or testing mode, enter 
the respective menu option to test the 
sensor signal strength.
2.  Walk across the area in front of the sensor 
again and check whether a good signal is 
received at your ULE compatible product.
NOTES
Once motion is detected, the sensor will only 
start to detect motion again after one minute. 
When you have received alerts already, you will 
only receive alerts again for motion detected 
after one minute.
If there is no alert received when you walk 
across the area in front of the sensor, move your 
ULE compatible product closer to the mounting 
location or move the sensor closer to the 
respective product.
Depending on surroundings and obstructing 
factors, like walls or cabinets, the sensor may 
not transmit to the ULE compatible product 
properly.
Mount the sensor
NOTES
This sensor must be mounted vertically on wall 
or at a corner. Do not mount the Motion Sensor 
in a horizontal orientation, or flat on the ceiling. 
Make sure the mounting surface is clean. A 
textured surface or any imperfections to a 
smooth surface can keep the mounting tape from 
making a strong bond.
This device detects or performs better when 
provided with a constant and stable environment. 
Avoid placing the sensor at a location which 
faces direct sunlight, or exposes to areas that 
may change temperature rapidly, or where there 
are air ducts or substantial airflows.
If you drill the holes into an object other than a 
stud, insert the screw anchors into the holes and 
tap gently on the ends with a hammer until the 
screw anchors are flush with the wall or ceiling.
Orientation of wall mount bracket:
The wall mount bracket’s vertical angle is not 
perpendicular to the Motion Senor. According 
to the mounting height selected, you need to 
orient the bracket sloping upward (number “5” 
up) or sloping downward (number “10” up).
Mounting height
Orientation of wall 
mount bracket
8.6 feet (2.6 meters) –  
10.6 feet (3.2 meters)
Number “10” up  
(sensor facing 
downward at 10° angle)
6.6 feet (2 meters) –  
8.6 feet (2.6 meters)
Number “5” up  
(sensor facing 
downward at 5° angle)
NOTES
For Pet-Immune Intrusion (human-only) 
Detection, it is better to mount the sensor higher.
The illustrations used in the mounting steps are 
with number “10” up in the wall mount bracket.
Mount on a corner of the wall
Place the wall mount bracket on a corner 
of the wall and then use a pencil to mark 
the top and the bottom holes as shown. 
Remove the wall mount bracket and drill 
two holes in the corner (7/32 inch drill bit).
If you drill the holes into a stud, go to  
step 3. 
-OR- 
If you drill the holes into an object other 
than a stud, insert the wall anchors into 
the holes. Tap gently on the ends with a 
hammer until the wall anchors are flush 
with the corner of the wall.
Align the wall mount bracket and screws 
with the holes in the corner of the wall as 
shown. Tighten the screws so that the wall 
mount bracket position is fixed.
1.
2.
3.
Congratulations
on purchasing your new VTech product.  
Before using this product, please read 
Important safety instructions.
This manual has instructions on how to 
set up and register your new sensor. For 
instructions on sensor settings, see the user’s 
manual that came with your ULE compatible 
products. Visit  
www.vtechphones.com/wireless-monitoring 
for a list of the latest ULE compatible products.
You may also view or download the online 
User’s manual of the respective product 
for a full set of installation and operation 
instructions at 
www.vtechphones.com.  
In Canada, visit 
www.vtechcanada.com.
Introduction
Stay on top of activity in your home, whether 
it is unwanted visitors or the kids coming and 
going. This sensor will let you know when it 
detects activity. 
This Motion Sensor has two types of  
motion-detection functions: 
Pet-Immune 
Intrusion Detection (for major motions of 
adults) and 
Occupancy Detection (for minor 
motions of adults, babies, or pets).
What’s in the box
Your product package contains the following items. 
Save your sales receipt and original packaging in 
the event warranty service is necessary.
Motion Sensor overview
1 –  Motion detector
2 –  LED light
Green for a half second when the sensor 
is powered on.
Flashes green when the sensor is in the 
pairing mode.
3 –  PAIR button 
Press and hold to enter the pairing 
mode.
4 –  Magnetic holder 
5 –  Battery compartment cover
Before use
Install Motion Sensor Battery
NOTES
Use only CR123A Lithium Battery.
When inserting battery, ensure polarities are 
correct.
For proper operation, use battery within the 
following temperature range: 0°F (-18°C) and 
120°F (49°C).
Slide open battery compartment cover.
Insert the battery into the battery 
compartment.
Slide the battery compartment cover back 
until it securely clicks into place.

1.
2.
3.
Add and register a sensor
Your new 
VC7017 Motion Sensor can be 
registered to any ULE compatible product.
Register each sensor individually to the 
respective ULE compatible product before use.
Register a Motion Sensor:
Enter the registration mode by selecting 
the option for adding a sensor in your 
ULE compatible product. Refer to the 
user’s manual of your ULE compatible 
product for more detailed instructions.
Press and hold the 
PAIR button on the 
Motion Sensor for 3 seconds, until the 
LED light at the front side flashes green. 
The sensor is now registering to the ULE 
compatible product.
The registration process takes about 
90 seconds to complete. When this 
registration process completes, the LED 
light on the sensor will remain steadily on for 
approximately two seconds then, will turn off.
If registration fails, remove the battery from 
the sensor and wait for a few seconds. 
Then, re-install the battery and wait until the 
LED light stops flashing. After that, begin 
registration process again.
NOTES
Make sure you do not press the 
PAIR button 
again once released after 3 seconds. Otherwise, 
the sensor will enter the testing mode.
You can also download online User’s manuals at 
www.vtechphones.com/support/manuals.
Replacing a sensor
If you have purchased this new 
VC7017 
accessory sensor to replace an old sensor, 
you must deregister the registered sensor 
first, and then register this new sensor to your 
ULE compatible product.
Deregister a sensor or all sensors:
Refer to the User’s manual of your ULE 
compatible products to deregister a sensor 
or all sensors.
1.
2.
VC7017
Accessory Motion Sensor 
for use with  
ULE certified systems
*
User’s manual
Motion Sensor
Go to www.vtechphones.com 
to register your product for 
enhanced warranty support and 
the latest VTech product news.
Lithium battery
User’s 
manual
User’s manual
Screws for 
wall mount 
bracket
Visit 
www.vtechphones.com/wireless-monitoring for the latest ULE compatible products.
Anchors for 
wall mount 
bracket
e  
b  
a  
c
d  
Wall mount bracket
Wall mount bracket 
covers (flat/corner)
Mounting height:
8.6 feet (2.6 meters) –  
10.6 feet (3.2 meters)
Mounting height:
6.6 feet (2 meters) –  
8.6 feet (2.6 meters)
Side View - Flat Wall Mounting
Side View - Flat Wall Mounting
8.6 feet (2.6 meters) - 10.6 feet (3.2 meters)  
You need to orient the bracket sloping  
10° downward (see 
Mount the sensor).
6.6 feet (2 meters) - 8.6 feet (2.6 meters) 
You need to orient the bracket sloping  
5° downward (see 
Mount the sensor).
Place the Motion Sensor facing away from large windows.
Top View - Corner Mounting
Shooting area
19.7 inches
60 degrees
22.8 inches
Shooting area
19.7 
inches
50 degrees
18.3
inches
63 inches
90
o
Intr
usio
De
tec
tion
Oc
cup
anc
De
tec
tion
Place the Motion Sensor facing away from large windows.
Top View - Corner Mounting
Shooting area
19.7 inches
60 degrees
22.8 inches
Shooting area
19.7 
inches
50 degrees
18.3
inches
63 inches
90
o
Intr
usio
De
tec
tion
Oc
cup
anc
De
tec
tion
Height: 7.6 feet (2.3 meters)
Detection 
area
5.5 feet (1.7 meters)
36
o
Detection 
area
48
o
Height: 10 feet (3.3 meters)
6 feet (2 meters)
31
o