VTech Telecommunications Ltd 80-0720-00 ユーザーズマニュアル
Motion detection
The Motion Sensor detects motion with one-minute cool off time. Once motion is detected, the
sensor will start detecting motion again only after one minute.
Pet-Immune Intrusion Detection detects the major motion of a person over several steps of
Pet-Immune Intrusion Detection detects the major motion of a person over several steps of
walking, while
Occupancy Detection detects the relatively minor motions of sedentary occupants
such as adults, babies, and pets in a room. Pet-Immune Intrusion Detection is designed to
discern humans from small animals, so that the sensor can report movement of persons in
locked/unoccupied areas, while allowing pets to roam about such areas without being reported.
The sensor detects motion horizontally within a 90° angle, and vertically within a 48° angle. The
The sensor detects motion horizontally within a 90° angle, and vertically within a 48° angle. The
detection area covers up to
20 X 20 feet. For the most complete coverage of a rectangular room, it
is recommended to mount the sensor in a corner of the room.
The Motion Sensor should be placed facing away from large windows. To provide the best
The Motion Sensor should be placed facing away from large windows. To provide the best
detection performance, it is recommended to mount the Motion Sensor with its wall mount bracket
on the corner or the wall, within one of the two height ranges:
NOTE
The numerical values in the illustrations are for conceptual reference only. The actual angles and distances
may vary upon the change in the mounted height of the sensor.
•
Check the sensor before use
1. Place the sensor about
3.3 feet (1 meter)
from the ULE compatible product.
2. Press and hold the
PAIR button on the
Motion Sensor for 3 seconds.
3. Release and immediately press the
PAIR
button again to enter the test mode until
the green LED is steadily on. The test
mode will last for 5 minutes.
4. Walk across the area in front of the sensor.
The green LED on the sensor will flash.
You will receive notifications at your
You will receive notifications at your
ULE compatible product. Refer to the
Installation guide or user’s manual of
your ULE compatible product for the
sensor alerts.
sensor alerts.
NOTES
Make sure you have done step 3 right after
step 2. Otherwise, the sensor will enter the
pairing mode.
In the test mode, once motion is detected, the
sensor will only start to detect motion again after
5 seconds.
In the normal mode, once motion is detected,
the sensor will only start to detect motion again
after one minute. When you have received alerts
already, you will only receive alerts again for
motion detected after one minute.
step 2. Otherwise, the sensor will enter the
pairing mode.
In the test mode, once motion is detected, the
sensor will only start to detect motion again after
5 seconds.
In the normal mode, once motion is detected,
the sensor will only start to detect motion again
after one minute. When you have received alerts
already, you will only receive alerts again for
motion detected after one minute.
•
•
•
•
•
•
Test the sensor signal strength
You can mount the Motion Sensor at a
location where family members or unwanted
visitors are likely to be coming and going.
1. Take the sensor to the desired mounting
1. Take the sensor to the desired mounting
location and then, temporarily mount it
at the desired height (Refer to
Motion
detection section). Use adhesive tape to
hold the bracket temporarily in place.
If your ULE compatible product has a
signal checking or testing mode, enter
the respective menu option to test the
sensor signal strength.
2. Walk across the area in front of the sensor
again and check whether a good signal is
received at your ULE compatible product.
received at your ULE compatible product.
NOTES
Once motion is detected, the sensor will only
start to detect motion again after one minute.
When you have received alerts already, you will
only receive alerts again for motion detected
after one minute.
If there is no alert received when you walk
across the area in front of the sensor, move your
ULE compatible product closer to the mounting
location or move the sensor closer to the
respective product.
Depending on surroundings and obstructing
start to detect motion again after one minute.
When you have received alerts already, you will
only receive alerts again for motion detected
after one minute.
If there is no alert received when you walk
across the area in front of the sensor, move your
ULE compatible product closer to the mounting
location or move the sensor closer to the
respective product.
Depending on surroundings and obstructing
factors, like walls or cabinets, the sensor may
not transmit to the ULE compatible product
properly.
•
•
•
•
Mount the sensor
NOTES
This sensor must be mounted vertically on wall
or at a corner. Do not mount the Motion Sensor
in a horizontal orientation, or flat on the ceiling.
Make sure the mounting surface is clean. A
Make sure the mounting surface is clean. A
textured surface or any imperfections to a
smooth surface can keep the mounting tape from
making a strong bond.
This device detects or performs better when
This device detects or performs better when
provided with a constant and stable environment.
Avoid placing the sensor at a location which
faces direct sunlight, or exposes to areas that
may change temperature rapidly, or where there
are air ducts or substantial airflows.
If you drill the holes into an object other than a
If you drill the holes into an object other than a
stud, insert the screw anchors into the holes and
tap gently on the ends with a hammer until the
screw anchors are flush with the wall or ceiling.
screw anchors are flush with the wall or ceiling.
Orientation of wall mount bracket:
The wall mount bracket’s vertical angle is not
perpendicular to the Motion Senor. According
to the mounting height selected, you need to
orient the bracket sloping upward (number “5”
up) or sloping downward (number “10” up).
The wall mount bracket’s vertical angle is not
perpendicular to the Motion Senor. According
to the mounting height selected, you need to
orient the bracket sloping upward (number “5”
up) or sloping downward (number “10” up).
Mounting height
Orientation of wall
mount bracket
mount bracket
8.6 feet (2.6 meters) –
10.6 feet (3.2 meters)
10.6 feet (3.2 meters)
Number “10” up
(sensor facing
downward at 10° angle)
(sensor facing
downward at 10° angle)
6.6 feet (2 meters) –
8.6 feet (2.6 meters)
8.6 feet (2.6 meters)
Number “5” up
(sensor facing
downward at 5° angle)
(sensor facing
downward at 5° angle)
NOTES
For Pet-Immune Intrusion (human-only)
Detection, it is better to mount the sensor higher.
The illustrations used in the mounting steps are
The illustrations used in the mounting steps are
with number “10” up in the wall mount bracket.
•
•
•
•
•
•
Mount on a corner of the wall
Place the wall mount bracket on a corner
of the wall and then use a pencil to mark
the top and the bottom holes as shown.
Remove the wall mount bracket and drill
two holes in the corner (7/32 inch drill bit).
If you drill the holes into a stud, go to
step 3.
-OR-
If you drill the holes into an object other
-OR-
If you drill the holes into an object other
than a stud, insert the wall anchors into
the holes. Tap gently on the ends with a
hammer until the wall anchors are flush
with the corner of the wall.
Align the wall mount bracket and screws
with the holes in the corner of the wall as
shown. Tighten the screws so that the wall
mount bracket position is fixed.
1.
2.
3.
Congratulations
on purchasing your new VTech product.
Before using this product, please read
Important safety instructions.
This manual has instructions on how to
This manual has instructions on how to
set up and register your new sensor. For
instructions on sensor settings, see the user’s
manual that came with your ULE compatible
products. Visit
www.vtechphones.com/wireless-monitoring
for a list of the latest ULE compatible products.
You may also view or download the online
You may also view or download the online
User’s manual of the respective product
for a full set of installation and operation
instructions at
www.vtechphones.com.
In Canada, visit
www.vtechcanada.com.
Introduction
Stay on top of activity in your home, whether
it is unwanted visitors or the kids coming and
going. This sensor will let you know when it
detects activity.
This Motion Sensor has two types of
This Motion Sensor has two types of
motion-detection functions:
Pet-Immune
Intrusion Detection (for major motions of
adults) and
Occupancy Detection (for minor
motions of adults, babies, or pets).
What’s in the box
Your product package contains the following items.
Save your sales receipt and original packaging in
the event warranty service is necessary.
Motion Sensor overview
1 – Motion detector
2 – LED light
Green for a half second when the sensor
is powered on.
Flashes green when the sensor is in the
Flashes green when the sensor is in the
pairing mode.
3 – PAIR button
Press and hold to enter the pairing
mode.
mode.
4 – Magnetic holder
5 – Battery compartment cover
•
•
•
Before use
Install Motion Sensor Battery
NOTES
Use only CR123A Lithium Battery.
When inserting battery, ensure polarities are
When inserting battery, ensure polarities are
correct.
For proper operation, use battery within the
following temperature range: 0°F (-18°C) and
120°F (49°C).
For proper operation, use battery within the
following temperature range: 0°F (-18°C) and
120°F (49°C).
Slide open battery compartment cover.
Insert the battery into the battery
compartment.
Slide the battery compartment cover back
until it securely clicks into place.
•
•
•
•
1.
2.
3.
Add and register a sensor
Your new
VC7017 Motion Sensor can be
registered to any ULE compatible product.
Register each sensor individually to the
Register each sensor individually to the
respective ULE compatible product before use.
Register a Motion Sensor:
Enter the registration mode by selecting
the option for adding a sensor in your
ULE compatible product. Refer to the
user’s manual of your ULE compatible
product for more detailed instructions.
Press and hold the
Press and hold the
PAIR button on the
Motion Sensor for 3 seconds, until the
LED light at the front side flashes green.
The sensor is now registering to the ULE
compatible product.
The registration process takes about
90 seconds to complete. When this
registration process completes, the LED
light on the sensor will remain steadily on for
approximately two seconds then, will turn off.
If registration fails, remove the battery from
If registration fails, remove the battery from
the sensor and wait for a few seconds.
Then, re-install the battery and wait until the
LED light stops flashing. After that, begin
registration process again.
NOTES
Make sure you do not press the
PAIR button
again once released after 3 seconds. Otherwise,
the sensor will enter the testing mode.
You can also download online User’s manuals at
You can also download online User’s manuals at
www.vtechphones.com/support/manuals.
Replacing a sensor
If you have purchased this new
VC7017
accessory sensor to replace an old sensor,
you must deregister the registered sensor
first, and then register this new sensor to your
ULE compatible product.
Deregister a sensor or all sensors:
Refer to the User’s manual of your ULE
compatible products to deregister a sensor
or all sensors.
1.
2.
•
•
•
VC7017
Accessory Motion Sensor
for use with
ULE certified systems
*
User’s manual
Motion Sensor
Go to www.vtechphones.com
to register your product for
enhanced warranty support and
the latest VTech product news.
to register your product for
enhanced warranty support and
the latest VTech product news.
Lithium battery
User’s
manual
User’s manual
Screws for
wall mount
bracket
*
Visit
www.vtechphones.com/wireless-monitoring for the latest ULE compatible products.
Anchors for
wall mount
bracket
e
b
a
c
d
d
Wall mount bracket
Wall mount bracket
covers (flat/corner)
Mounting height:
8.6 feet (2.6 meters) –
10.6 feet (3.2 meters)
8.6 feet (2.6 meters) –
10.6 feet (3.2 meters)
Mounting height:
6.6 feet (2 meters) –
8.6 feet (2.6 meters)
6.6 feet (2 meters) –
8.6 feet (2.6 meters)
Side View - Flat Wall Mounting
Side View - Flat Wall Mounting
8.6 feet (2.6 meters) - 10.6 feet (3.2 meters)
You need to orient the bracket sloping
10° downward (see
Mount the sensor).
6.6 feet (2 meters) - 8.6 feet (2.6 meters)
You need to orient the bracket sloping
5° downward (see
Mount the sensor).
Place the Motion Sensor facing away from large windows.
Top View - Corner Mounting
Shooting area
19.7 inches
60 degrees
22.8 inches
Shooting area
19.7
inches
50 degrees
18.3
inches
63 inches
90
o
Intr
usio
n
De
tec
tion
Oc
cup
anc
y
De
tec
tion
Place the Motion Sensor facing away from large windows.
Top View - Corner Mounting
Shooting area
19.7 inches
60 degrees
22.8 inches
Shooting area
19.7
inches
50 degrees
18.3
inches
63 inches
90
o
Intr
usio
n
De
tec
tion
Oc
cup
anc
y
De
tec
tion
Height: 7.6 feet (2.3 meters)
Detection
area
5.5 feet (1.7 meters)
36
o
Detection
area
48
o
Height: 10 feet (3.3 meters)
6 feet (2 meters)
31
o