Itron Inc. 500GA Benutzerhandbuch

Seite von 54
Elster American Meter Installation 
 
3.  Unscrew one index mounting screw completely. Hold one hand under the index to catch the screw. While 
you remove the other mounting screw, pull the index away from the meter to keep the index backplate 
against the back of the screw. Remove the screw completely after the index is free of the meter.  
 
Set the index aside where it will not be damaged or fill with dirt, rain or snow. You will mount the index 
to the ERT module later in this procedure.  
4.  Verify the index mounting screws are 3/16-inch long and not corroded. If the screws are the correct length 
and not corroded, retain for later use. If you discarded the original screws, use the correct replacement 
screws (see Installation Prerequisites). 
5.  Remove the old gasket, gasket residue and dirt from the meter (if applicable). The meter face must be free 
of gasket residue and foreign materials before you install the 500G ERT module.  
 
 
Assembling the 500G ERT Module and Index 
Continue the ERT module installation by assembling the ERT module and index. 
 
To assemble the 500G ERT module and index 
1.  Separate the ERT module housing from the cover by pulling the cover straight out from the housing. 
 
TDC-1671-000 OpenWay Riva 500G Gas ERT Module Installation Guide, Direct Mount 
10 
 
Proprietary and Confidential