This manual describes how to install, program and maintain the PC5132.
Before you install the PC5132 module, you should have completed the following
steps in your system installation:
1. Plan the installation and wiring of the security system (see your system
Installation Manual)
2. Install the control panel, and install and enroll at least one keypad to use
for programming.
3. Install and enroll any hardwired zone expander modules (PC5108) you
plan to use.
NOTE: PC5108 zone expander modules occupy zones in 2 groups of 4 (e.g.
zones 9-12 and zones 13-16). None of the zones assigned to a PC5108 module
may be used for wireless devices.
Program the PC5132 from a system keypad or using downloading software on
a remote computer (e.g. DLS-1). Read your system Installation Manual for more
information.
1.1 How to use this Manual
Read this manual before you begin installing the PC5132. To install and set up
the PC5132 and wireless devices, follow these steps. Refer to the sections listed
below.
1. Temporarily mount  and wire the PC5132 module (see 
Section 2)
2. Enroll and program wireless devices (see 
Section 3)
3. Complete zone and other programming on the system (see 
Section 4)
4. Test the placement of all the wireless devices 
(see Section 5)
5. Permanently mount the PC5132 receiver and wireless devices 
(see
Section 5)
For additional information on trouble conditions, RF jamming signal detection
and battery replacement, see 
Section 6.
For help with troubleshooting, see 
Section 7.
1.2 Specifications and Features
• Current Draw: 80 mA
• Frequency: 433 MHz
• Zones - receiver can receive signals from up to 32 wireless zones
• Antenna - diversity design for enhanced performance
• Supervisory - programmable supervisory window, 1 to 24 hours, in 15
minute increments
• Location
- can be wired up to 750 ft. / 230 m from the main panel with 22 gauge wire
- connects to Keybus
- for longer wire runs, thicker gauge wire must be used.
• Compatibility: The PC5132 v3.12 can be connected to the following
panels:
 
PC501X, PC5008,  PC1565, PC585
S E C T I O N  1
Introduction