Digital Security Controls Ltd. 02CL3050 Benutzerhandbuch

Seite von 28
Skyroute CL3050  Standalone Wireless Communicator
8
5 System Programming
The Skyroute CL3050 is programmed using a PowerSeries keypad. Refer to    
Section 1.1 Specifications.
Note:
Power down the Skyroute CL3050 when connecting or removing 
other Keybus modules from the system
. If the Skyroute CL3050 is con-
nected to a control panel (mode 1), the control panel must also be 
powered down
.
1.
Connect keypad Keybus connections to the RED, BLK, YEL and GRN termi-
nals of the Skyroute CL3050.  
2.
Connect a +12VDC supply across the RED and BLK terminals.  
Upon detecting the keypad on power up, the Skyroute CL3050 will begin 
driving Keybus and will blank the keypad with all LEDs and icons off. 
3.
Press the star [*] key to gain access to the programming section. 
Programming is done with a 2-digit section entry.  When programming is 
complete, power down the Skyroute CL3050 and remove the keypad.
To Keybus
Connections
on Keypad
Not Connected
RED    BLK   YEL  GRN  COM  PGM