ADCP-75-126 • Issue B • April 2002 • Section 5: Maintenance
Page 5-2
©
 2002, ADC Telecommunications, Inc.
• Battery
  maintenance  tools  (see  PRC-SERIES  OPERATING  AND  FIELD  SERVICE
MANUAL
 for tool recommendations)
2
FAULT DETECTION AND ALARM REPORTING
The
 Digivance LRCS on-board embedded software detects various unit and system faults and
reports
  them  as  either  Major or Minor  alarms.  A  Major alarm indicates  that  the  system  has
failed
 in a way that directly affects RF transport performance. This usually means that some
calls
 or perhaps all calls cannot be made over the system. A Minor alarm means that system
performance
 is not affected or in some cases, that the performance may no longer be optimal.
Four
 types of faults cause a minor alarm to be reported: overtemperature, fan failure, diversity
path
 failure, and an external minor fault (user defined fault). All other faults are reported as a
Major
 alarm. 
Reporting
 of Major and Minor alarms is accomplished through the HU alarm contacts, the unit
front
  panel  LED’s,  the  EMS  software  Graphical  User  Interface  (GUI),  and  the  Network
Operations
 Center - Network Element Manager (NOC/NEM) interface.
The
 HU is equipped with a set of both normally open (NO) and normally closed (NC) alarm
contacts
 which are used to report both Major and Minor alarms to an external alarm system. The
alarm
 contacts summarize the inputs so that any Major or Minor alarm will trigger an alarm
report
 to the external alarm system. 
The
 HU, STM, and LPA front panel LED indicators are used to report specific alarms which are
reflected
 in the LED colors: Green, Red, Yellow, and Off. In addition to LED indicators, the
LPA
 is also equipped with a Digital Display that provides status messages. A description of the
Host
  Unit,  Spectrum  Transport  Module,  and  Linear  Power  Amplifier  LED  indicators  is
provided
 respectively in 
 and 
 
The
 EMS software GUI provides both a summary and a more detailed list of alarm information
that
  includes  unit  and  module  level  faults,  circuit  faults,  and  measured  value  faults  such  as
voltages,
 RF power, and temperature. A summary showing a list of all systems and their current
alarm
  status  is  presented  through  the  Alarm  OverView  display.  A  detailed  list  of  alarm
information
 is presented through the HOST alarm display and the REMOTE alarm display. All
the
  inputs  that  the  system  reports  as  alarms  are  shown  in  the  HOST  and  REMOTE  alarm
displays.
 
The
 NOC/NEM interface provides the same summary and detailed list of alarm information as
the
  EMS  software  GUI  but  in  an  ASCII  text  string  format.  Sending  the  command  GET
ALARMSUMMARY
 produces a list of all systems and their current alarm status. Sending the
command
  GET  ALARM  ALL  for  a  specific  system  will  produce  a  detailed  list  of  alarm
information
 for the specified system.