SECTION 5: MAINTENANCE
_________________________________________________________________________________________________________
1
SYSTEM MAINTENANCE OVERVIEW
This
section explains the Digivance LRCS fault detection and alarm reporting system, provides
a
method for isolating and troubleshooting faults, and provides test and maintenance
procedures.
The Digivance LRCS requires minimal regular maintenance to insure continuous
and
satisfactory operation. Components that require regular replacement, cleaning, or testing
include
the HU and RU fans and the RU air-filter and back-up battery,
Maintenance
also includes diagnosing and correcting service problems as they occur. When an
alarm
is reported, it will be necessary to follow a systematic troubleshooting procedure to locate
the
problem. Once the source of the problem is isolated, the appropriate corrective action can be
taken
to restore service. The only internal components that can be replaced are the cooling fans
which
mount in the HU, RU, and LPA. The failure of any other component within a unit will
required
replacement of that unit.
1.1
Tools and Materials
The
following tools and materials are required in order to complete the procedures in this
section:
• ESD
wrist strap
• IR
filtering safety glasses
• Patch
cords with SC connectors
• 15
dB in-line SC optical attenuators
• Optical
power meter (1550 and 1310 nm)
• Laser
light source
• TORX
screwdriver (with T10 bit)