ADCP-75-126 • Issue B • April 2002 • Section 5: Maintenance
Page 5-1
©
 2002, ADC Telecommunications, Inc.
SECTION 5: MAINTENANCE
_________________________________________________________________________________________________________
1
SYSTEM MAINTENANCE OVERVIEW
This
 section explains the Digivance LRCS fault detection and alarm reporting system, provides
a
  method  for  isolating  and  troubleshooting  faults,  and  provides  test  and  maintenance
procedures.
 The Digivance LRCS requires minimal regular maintenance to insure continuous
and
 satisfactory operation. Components that require regular replacement, cleaning, or testing
include
 the HU and RU fans and the RU air-filter and back-up battery, 
Maintenance
 also includes diagnosing and correcting service problems as they occur. When an
alarm
 is reported, it will be necessary to follow a systematic troubleshooting procedure to locate
the
 problem. Once the source of the problem is isolated, the appropriate corrective action can be
taken
 to restore service. The only internal components that can be replaced are the cooling fans
which
 mount in the HU, RU, and LPA. The failure of any other component within a unit will
required
 replacement of that unit. 
1.1
Tools and Materials
The
  following  tools  and  materials  are  required  in  order  to  complete  the  procedures  in  this
section:
 
• ESD
 wrist strap
• IR
 filtering safety glasses
• Patch
 cords with SC connectors
• 15
 dB in-line SC optical attenuators
• Optical
 power meter (1550 and 1310 nm)
• Laser
 light source
• TORX
 screwdriver (with T10 bit)