ADCP-75-114 • Issue C • June 2001 
Page 12 
©
 2001, ADC Telecommunications, Inc. 
16169-A
 
Figure 8. Chassis Ground Stud 
  6.  Cut the chassis grounding wire to length and connect it to the approved ground source as 
required
 by local code or practice.  
    Note: Be sure to maintain reliable grounding for rack and wall mounted equipment. Pay 
particular
 attention to ground source connections. 
2.5  Coaxial Cable Connections 
The
 RF signal connections between the RIU and DHU are supported through a pair of type N 
female
 connectors mounted on the RIU front panel. One connector is used for connecting the 
forward
  path  coaxial  cable  and  the  other  connector  is  used  for  connecting  the  reverse  path 
coaxial
 cable. The RF signal connection between the RIU and the donor antenna is supported 
through
  a  single  type  N  female  connector.  The  single  connector  is  used  for  connecting  the 
coaxial
 jumper cable that links the RIU to the donor antenna.  
2.5.1  Forward and Reverse Path Coaxial Cable Connections 
Use
 the following procedure to install the forward and reverse path coaxial cables that link the 
RIU
 to the DHU:  
  1.  Locate the forward and reverse path coaxial cables that were routed to the RIU from the 
DHU.
  
    Note:  The procedures for routing the reverse and forward path coaxial cables from the 
DHU
 to the RIU and for connecting the cables to the DHU are covered in the Digivance 
ICS
 Installation and Operation Manual (ADCP-75-110) which is provided with the DHU.  
  2.  Terminate each cable with a type N male connector following the connector supplier’s 
recommendations.
  
  3.  Connect  the  forward  path  cable  to  the  FORWARD  OUT  connector  on  the  RIU  front 
panel
 as shown in Figure 9.