ADC Telecommunications Inc. DVICSRIU800 Benutzerhandbuch

Seite von 31
ADCP-75-114 • Issue C • June 2001 
Page 13 
©
 2001, ADC Telecommunications, Inc. 
16652-A
FORWARD OUT
CONNECTOR
REVERSE IN
CONNECTOR
TYPE-N MALE CONNECTOR
 
Figure 9. FORWARD OUT and REVERSE IN Coaxial Cable Connections 
  4.  Connect the reverse path cable to the REVERSE IN connector on the RIU front panel as 
shown
 in Figure 9.  
  5.  Dress and secure cables at the RIU.  
2.5.2  Antenna Coaxial Cable Connection 
Use
  the  following  procedure  to  install  the  coaxial  cable  that  links  the  RIU  to  the  donor 
antenna:
  
 
  Note: To comply with Maximum Permissible Exposure (MPE) requirements, antennas must be 
installed
 to provide at least 20 centimeters (8 inches) of separation from all persons per FCC 
47
 CFR part 2.1091.  
  1.  Obtain  the  required  length  of  high  performance,  flexible,  low  loss  50-ohm  coaxial 
communications
 cable for the antenna coaxial connection.  
  2.  Route the coaxial cable between the RIU and the donor antenna (per system design) and 
cut
 to the required length. Allow sufficient slack for dressing and organizing cables at the 
RIU
 and antenna.  
  3.  Terminate  each  cable  end  with  a  type  N  male  connector  following  the  connector 
supplier’s
 recommendations.  
  4.  Connect the RIU end of the antenna cable to the ANTENNA connector on the RIU front 
panel
 as shown in Figure 10.  
  5.  Connect the antenna end of the antenna cable to the donor antenna.  
  6.  Dress and secure cables at the RIU and donor antenna.