ADCP-75-134 • Issue A • April 2002 • Section 5: Maintenance
Page 5-5
©
 2002, ADC Telecommunications, Inc.
Table 5-3. Linear Power Amplifier LED Indicators and Digital Display
INDICATOR
COLOR
DESCRIPTION
FAIL
Off
Yellow
Indicates
 if the LPA is normal or faulty.
The
 LPA is normal.
Internal
 fault detected in the LPA.
SHUTDOWN
Off
Red
Indicates
 if the LPA has an RF output or if the RF output 
is
 shutdown. 
The
 LPA RF output is on.
The
 LPA RF output is shutdown. 
DISPLAY MESSAGE
DESCRIPTION
ADC850
0
 ALARMS
NORMAL
 OPERATION
The
 LPA is normal.
HUNG
 CHANG
ADC-850M
Appears
 every time power is turned on.
RESTART
 AT STAND
ALONE
 MODE
Appears
 when LPA is reset.
ADC-850S
Appears
 when an alarm has turned off and the LPA is restart-
ing
 after the RESET button has been pressed or the reset com-
mand
 has been supplied from an external source. 
PLEASE
 WAIT WHILE
RESTARTING
Appears
 while the LPA processor is rebooting. 
DC
 +12V: +12.0V
DC
 +27V: +27.0V
DC
 +32V: +32.0V
DC
 -12V: -12.0V
Alternately
 displays the voltage flow in each part of the LPA.
TEMPER
 100.0 ºC
Indicates
 the current temperature of the LPA heat sink.
OVER
 POWER ALARM
Output
 power has exceeded 100 W.
HIGH
 TEMPERATURE
Alarm:
 Temperature of LPA exceeds 85 ºC.
VSWR
 ALARM
Reflected
 LPA power exceeds 20 W.
LOOP
 FAIL
General
 fault occurred in the LPA loops. 
FANFAIL
One
 or more fans have failed. 
FORCED
 SHUTDOWN
The
 RF ON/OFF switch is in the OFF position or the LPA was 
set
 in the disable mode through the EMS computer. 
Alternating
 FORCED SHUTDOWN 
and
 alarm message
An
 alarm has remained for over 5 seconds.
DC
 FAIL
+12V
-12V
+32V
Voltage
 is outside the preset ranges:
+11
 to +13V
-13
 to -11V
+30
 to +34V