Measurement Systems International Inc DL7200RFH Benutzerhandbuch

Seite von 32
M E A S U R E M E N T  S Y S T E M S  I N T E R N A T I O N A L
Page 12     MSI-7200 Dyna-Link   
   User Guide
CALIBRATION UNIT(S)
Calibration units can be changed by scrolling through the choices with the UP
(PEAK) key or DOWN (ZERO) key and pushing ENTER (POWER) when the
desired unit is displayed. Available units are: lb (pounds), kg (kilograms), t
(short tons), daN (dekaNewtons), and kg X1000 (equivalent to Metric tons).
To change the calibration units
1) Push “SETUP/CAL”. See “General Setup Procedure”.
2) The display reads “Unit” (if not, push the UP or DOWN key to select the
Unit mode).
3) Push ENTER (POWER). You are now in the units menu and the current
units will be flashing.
4) Push UP/DOWN until the desired units are displayed, then push ENTER
 (POWER).
5) Now you are back in the Setup Menu. To go back to normal operation,
push CLEAR/CANCEL (ZERO and PEAK pushed simultaneously or
rear panel SETUP/CAL). Push the UP/DOWN keys to select other setup
functions, or scroll UP/DOWN to END and press ENTER.
CALIBRATION
To calibrate a Dyna-Link, the user is required to have an accurate test weight
system of adequate capacity.
To calibrate
1) Enable the Setup/Cal mode (See “General Setup Procedure”).
2) Ensure the proper units that you wish to calibrate in are selected (See
“Calibration Units”).
3) Push UP/DOWN until the display reads “CAL”.
4) Push ENTER (POWER). You are now in the CAL menu.
5) The display will flash “ZEro” for 2 seconds as a prompt to unload the
Dyna-Link for zeroing. (The number “2” is used to resemble a “Z”)
6) The display will blink while showing the current zero value. When the
zero reading is stable, push “ZERO”.
7) The display will flash “LOAd” as a prompt to load the Dyna-Link with
the calibration weight. A weight of at least 20% of capacity is required.
Note: A test weight of 50% or more of capacity is recommended for increased
accuracy.
8) The capacity of the Dyna-Link will be displayed next as a default setting