2) Push UP/DOWN until the display reads “FCAL”.
3) Push ENTER (POWER). You are now in the FCAL menu.
4) Apply a calibration weight of at least 50% of capacity.
5) The display will read the current gross weight if it is over 50% of
capacity otherwise it will read “—” and cannot be adjusted.
6) Use the DOWN (ZERO) key to cause the displayed weight to move
down slightly. Use the UP (PEAK) key to cause the reading to move up.
Each push of these two keys causes the calibration to shift by 1/4
displayed count. When the reading is acceptable (or you want to exit)
push ENTER (POWER).
7) Now you are back in the Setup Menu. Push CLEAR/CANCEL to return
to normal operation. (See “To Store a New RCAL”).
AUTOMATIC POWER OFF (“AOFF”)
The Automatic Power Off feature, when enabled, prolongs the battery life of
the Dyna-Link by turning the power off after ten minutes of non-use. Any time
a key is pressed, or the detected tension is in motion (tension changing by more
than two display counts), the ten minute limit is reset. Therefore, the Dyna-
Link will stay on indefinitely if the tension is changing or any key is pressed at
least once every ten minutes. The default factory setting is the Power Off
enabled mode. When disabled, the unit will stay on; only the power key will
turn it off. It is recommended in systems where the Set-Points are used for
safety warnings, that the Automatic Power Off feature is disabled.
To Enable or Disable Automatic Power Off
1) Push SETUP/CAL.
2) Push the UP (PEAK) or DOWN  (ZERO) key to scroll to the menu
function “AOFF”.
3) Push ENTER (POWER). You are now in the Auto Off menu and the
current selection will be flashing (either “On” or “OFF”).
4a) To disable Automatic Power Off (unit will always stay on), use the UP
(PEAK) key to scroll to “OFF”.
4b) To enable Automatic Power Off (unit will turn off automatically after ten
minutes of non-use), use the UP (PEAK) key to scroll to “On”.
5) Push ENTER (POWER). Now you are back in the Setup Menu. Push
CLEAR/CANCEL to return to normal operation.
AUTOMATIC ZERO TRACKING (“AZT”)
To Enable or Disable Automatic Zero Tracking   (Software versions X-10