1) Push SETUP/CAL.
2) Push the UP (PEAK) or DOWN  (ZERO) key to scroll to the menu
function “AZT” (displayed as “A2t”).
3) Push ENTER (POWER). You are now in the Auto Off menu and the
current selection will be flashing (either “On” or “OFF”).
4a) To disable AZT, use the UP (PEAK) key to scroll to “OFF”.
4b) To enable AZT , use the UP (PEAK) key to scroll to “ON”.
5) Push ENTER (POWER). Now you are back in the Setup Menu. Push
CLEAR/CANCEL to return to normal operation.
ERROR CODES
The Dyna-Link has internal error checking that can result in the display of an
error code.
Err
Unit is in overload. Reduce the tension on the Dyna-Link immediately.
Err1 A key is stuck. Make sure the front panel keys are not being depressed. If
Err1 persists, check the internal keys.
Err2 The EEROM is not functioning. Unit must be serviced.
Flashing value with minus sign
This will occur when negative readings exceed the display capacity
(usually results from a large tension value being zeroed out and then
removed).
RS232 (EIA232D) SERIAL OUTPUT
(Option: Remote Units Only)
The Remote Dyna-Link can be ordered with an RS-232 serial output option.
This output is used to drive printers or interface to computers for tension
recording and data logging.
To Print the Current Reading
Push the “*” key. The reading on the display will print out in the form:
#######spUUUsp**** where:
“#” = displayed tension (with a minus sign if needed),
sp = a space,
UUU = units (lbs, kgs, mtn [metric tons], ton [short tons], daN
[dekaNewtons]),
sp = a space,
and **** = “PEAK” if the Link is in the Peak mode or 4 spaces. The
transmission is terminated by a “Line Feed”.